11 ipmi command control, Table 4-32, Hpi restart daemon state – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual
Page 71: Table 4-33, Ipmi command rdr, Using hpi-b
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
71
4.5.11 IPMI Command Control
IPMI command control is used to execute IPMI commands on a given resource id. This control
is created for all the FRUs in the shelf. hpiipmi client application makes use of this control to
get the IPMI commands executed.
RdrTypeUnion.CtrlRec.WriteOnly
SAHPI_FALSE
RdrTypeUnion.CtrlRec.Oem
Assigned by HPI implementation.
RdrTypeUnion.CtrlRec.IdString
MOTHPI_CTRL_NAME_HPI_RESTART
_DAEMON
Table 4-32 HPI Restart Daemon State
SaHpiCtrlStateT
Value
Type
SAHPI_CTRL_TYPE_DIGITAL
StateUnion.Digital
SAHPI_CTRL_STATE_PULSE_ON |
SAHPI_CTRL_STATE_OFF
Table 4-31 HPI Restart Daemon RDR (continued)
SaHpiRdrT
Value
Table 4-33 IPMI Command RDR
SaHpiRdrT
Value
RecordId
Assigned by HPI implementation
RdrType
SAHPI_CTRL_RDR
Entity
Entity path of the FRU
Ex: {ADVANCEDTCA_CHASSIS,6}{FAN_TRAY_SLOT,1}
{COOLING_UNIT,1}
RdrTypeUnion
Defined in next table
IdString
MOTHPI_CTRL_NAME_BOOT_OPTION