This invokes the FUMI call saHpiFumiTargetVerify(). This call is intended to be invoked
after the upgrade has finished. It verifies the new, updated image at the target memory
matches with the source image. Refer to the FUMI specification for details.

-c

This invokes the FUMI call saHpiFumiUpgradeCancel().

This command is currently not supported.

-V

This invokes the version number of the hpifumi command itself.

-h

This displays help information, which includes parameter description and overall functionality
description.

-n COMPONENT_ID

The component identifier of the component for which the information is required.

-Z Rollback_disable

A Boolean value representing the value you want to set for the auto rollback status.

-I

Spec information for the underlying IPMC. Invokes the API saHpiSpecInfoGet().

-D

This provides service impact information while in case an IPMC is upgraded, there will be
impact on the Service provided by IPMC or not. Invokes the API
saHpiFumiServiceImpactGet()

.

-C

Source component Information, after the upgrade image has been validated you can view the
source component information provided by image. Invokes the API
saHpiFumiSourceComponentInfoGet()

.