Table 4-46, Virtual cooling resource - fan control, Table 4-47 – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual
Page 85: Virtual cooling resource - fan control states, Using hpi-b
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
85
Entity
Cooling resource entity
IsFru
Unused
RdrTypeUnion
CtrlRec
See
IdString
Fan Control
Table 4-46 Virtual Cooling Resource - Fan Control
SaHpiCtrlRecT
Value
Num
MOTHPI_CTRL_NUM_COOLING
OutputType
SAHPI_CTRL_GENERIC
Type
SAHPI_CTRL_TYPE_DISCRETE
TypeUnion.Analog.Min
Minimum blower speed level
TypeUnion.Analog.Max
Maximum blower speed level
TypeUnion.Analog.Default
Default blower speed level
DefaultMode.Mode
SAHPI_MODE_AUTO
DefaultMode.ReadOnly
SAHPI_FALSE
WriteOnly
SAHPI_FALSE
Table 4-47 Virtual Cooling Resource - Fan Control States
SaHpiCtrlStateT
Value
Type
SAHPI_CTRL_TYPE_ANALOG
StateUnion.Analog
Current fan level calculated by cooling algorithm.
This can always be read, independent of the cooling
mode (internal/external).
Table 4-45 Virtual Cooling Resource - Fan Control RDR (continued)
SaHpiRdrT
Value