67

4.5.8

HPI Daemon Switchover Control

This HPI control handles the switchover between the active and deactivated HPI-B daemon.
The location (active/deactivated) of the HBI daemon cannot be controlled directly. Instead,
this HPI control can be used to initiate a switchover. After the switchover is completed, if
eventing is enabled for the active HPI-B daemon sensor, the HPI Implementation will send an
event with the Resource Id of the new Resource hosting the active HBP daemon.

RdrTypeUnion.SensorRec.Thresh

oldDefn.ReadThold,

RdrTypeUnion.SensorRec.Thresh

oldDefn.WriteThold,

RdrTypeUnion.SensorRec.Thresh

oldDefn.Nonlinear

These values are not meaningful,
because the IsAccessible flag is set
to SAHPI_FALSE.

RdrTypeUnion.SensorRec.OEM

Assigned by HPI implementation

IdString

MOTHPI_SENSOR_ACTIVE_DAEM

ON_NAME

MOTHPI_SENSOR_STANDBY_DAE

MON_NAME

.

Table 4-25 Active and Stand-By HPI Daemon Sensors Reading

SaHpiSensorReadingT

Value

isSupported

SAHPI_TRUE

Type

SAHPI_SENSOR_READING_TYPE_UINT64

Value

ResourceId in least significant 32 bits if one is present,
otherwise SAHPI_UNSPECIFIED_RESOURCE_ID

Table 4-26 Active and Stand-By HPI Daemon Sensors Event State

SaHpiEventStateT

Value

EventState

SAHPI_ES_PRESENT | SAHPI_ES_ABSENT

Table 4-24 Active and Stand-By HPI Daemon Sensors RDRs (continued)

SaHpiRdrT

Value

Notes