9 failed slot restore control, Table 4-29, Failed slot restore control rdr – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual
Page 69: Using hpi-b
Using HPI-B
System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)
69
4.5.9
Failed Slot Restore Control
"Failed Slot Restore Control" control enables the user to initiate a re-discovery of the resource in
the slot and sets the ResourceFailed flag in RPT to false. The ResourceFailed flag in
the RPT Entry of slot resource is set to true if the discovery of the resource in the slot fails, or
the resource in the slot is in failed state. The ResourceFailed flag of the slot resource can be
set to false in any one of the following conditions:
1. Resource in failed state is removed using saHpiResourceFailedRemove().
2. If any of the resource is inserted into the failed slot.
An example application hpislotrestore can be used to set and get the new control "Failed
Slot Restore" state.
Table 4-29 Failed Slot Restore Control RDR
SaHpiRdrT
Value
Notes
RecordId
Assigned by HPI implementation.
RdrType SAHPI_CTRL_RDR
Entity
Entity path of the slot resource.
IsFru SAHPI_FALSE
RdrTypeUnion.CtrlRec.Num
MOTHPI_CTRL_FAILED_SLOT_RESTOR
E_NUM
RdrTypeUnion.CtrlRec.Type
SAHPI_CTRL_TYPE_DIGITAL
RdrTypeUnion.CtrlRec.Output
Type
SAHPI_CTRL_GENERIC
RdrTypeUnion.CtrlRec.TypeUn
ion.Digital.Default
SAHPI_CTRL_STATE_OFF
RdrTypeUnion.CtrlRec.Defaul
tMode.Mode
SAHPI_CTRL_MODE_MANUAL
RdrTypeUnion.CtrlRec.Defaul
tMode.ReadOnly
SAHPI_TRUE
RdrTypeUnion.CtrlRec.WriteO
nly
SAHPI_FALSE
RdrTypeUnion.CtrlRec.OEM
Assigned by HPI implementation.