Using hpi-b – Artesyn System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User's Guide (June 2014) User Manual

Page 62

Advertising
background image

Using HPI-B

System Management Interface Based on HPI-B (Centellis 2000 R3.0/4411) User’s Guide (6806800P20C)

62

IsFru

SAPHI_FALSE

Per the rules
stated in [HPI],
the IsFru flag is
not applicable
when the
Management
Instrument is
directly
associated with
the Resource, as
is the case here.

RdrTypeUnion.SensorRec.Num

MOTHPI_SENSOR_NUM_DAEMO

N_REDUNDANCY

RdrTypeUnion.SensorRec.Type

SAHPI_OPERATIONAL

RdrTypeUnion.SensorRec.Catego

ry

SAHPI_EC_REDUNDANCY

RdrTypeUnion.SensorRec.Enable

Ctrl

True if the HPI User can enable or
disable the Sensor via
saHpiSensorEnableSet()

RdrTypeUnion.SensorRec.EventC

trl

SAHPI_SEC_PER_EVENT |

SAHPI_SEC_READ_ONLY_MAS

KS | SAHPI_SEC_READ_ONLY

RdrTypeUnion.SensorRec.Events

SAHPI_ES_FULLY_REDUNDAN

T |

SAHPI_ES_NON_REDUNDANT_

SUFFICIENT_RESOURCES |

SAHPI_ES_NON_REDUNDANT_

INSUFFICIENT_RESOURCES

RdrTypeUnion.SensorRec.DataFo

rmat.IsSupported

SAHPI_FALSE

RdrTypeUnion.SensorRec.DataFo

rmat.ReadingType

Not Applicable

RdrTypeUnion.SensorRec.DataFo

rmat.BaseUnits

Not Applicable

RdrTypeUnion.SensorRec.DataFo

rmat.ModifierUnits

Not Applicable

Table 4-21 HPI Daemon Redundancy Sensor RDR (continued)

MotHpiRdrT

Value

Notes