Mathey Dearman CNC Saddle Machine User Manual

Page 115

Advertising
background image

CNC Saddle Machine Parts & Operating Manual 03-0117-MSA 03-0117-1SA 03-0117-2SA

Ver 1.0

115

Table 7-1

Electronic Troubleshooting

Symptom

Possible Cause(s)

Corrective Action

No Red Light

No Electric Power

Plug into 115 or 230 power source

E Stop Switch is not released

Twist to release the E Stop Switch

No Blue Light

USB Cable is not connected.

Turn off power to machine, connect USB cable to Mathey CNC
machine & computer.

Software was opened before E
Stop Switch was released.

Turn off software & power to the machine. Turn on the machine
first, then open the software.

Machine hits End Limit

Switch and stops.

The Yellow Power Cord has
been severed.

Replace Yellow Power Cord and recalibrate.

Limit Switch has failed.

Replace limit switch and recalibrate.

Laptop cursor jumps

around screen when
plasma torch is fired

Plasma is emitting high
frequency

Move laptop as far away from the CNC machine as possible.
Ensure all plasma cables & ground cables are not touching USB
cable.

Advertising