Eaa monitor policies, Elements in a monitor policy, Event – H3C Technologies H3C S6300 Series Switches User Manual

Page 208

Advertising
background image

195

RTM

RTM manages the creation, state machine, and execution of monitor policies.

EAA monitor policies

A monitor policy specifies the event to monitor and actions to take when the event occurs.
You can configure EAA monitor policies by using the CLI or Tcl.
A monitor policy contains the following elements:

One event.

At least one action.

At least one user role.

One running time setting.

For more information, see "

Elements in a monitor policy

."

Elements in a monitor policy

Event

Table 19

shows types of events that EAA can monitor.

Table 19 Monitored events

Event type Description

CLI

CLI event occurs in response to monitored operations performed at the CLI. For example,
a command is entered, a question mark (?) is entered, or the Tab key is pressed to
complete a command.

Syslog

Syslog event occurs when the information center receives the monitored log within a
period.

NOTE:

The log generated by the EAA RTM does not trigger the monitor policy to run.

Process

Process event occurs in response to a state change (caused by an automatic system task)
of the monitored process (such as an exception, shutdown, start, or restart).

Hotplug

Hotplug event occurs when a master/subordinate switchover occurs, or when a device
joins or leaves the IRF fabric.

Interface

Each interface event is associated with two user-defined thresholds: start and restart.
An interface event occurs when the monitored interface traffic statistic crosses the start

threshold in the following situations:

The statistic crosses the start threshold for the first time.

The statistic crosses the start threshold each time after it crosses the restart threshold.

SNMP

Each SNMP event is associated with two user-defined thresholds: start and restart.
SNMP event occurs when the monitored MIB variable's value crosses the start threshold
in the following situations:

The monitored variable's value crosses the start threshold for the first time.

The monitored variable's value crosses the start threshold each time after it crosses the

restart threshold.

Advertising