Teampos 3000 front panel switch and lcd matrix – FUJITSU TeamPoS 3000 XL User Manual

Page 15

Advertising
background image

TeamPoS 3000 XL and XL

2

Overview

D900000145

Issue 3

1-5

1.3.1.

TeamPoS 3000 Front Panel Switch and LCD Matrix

Symbols

Name
Switch/LED

Mounting Position

LED

Color

Remark

Power Switch

Under drop down
window in front panel

--

Depending on the BIOS setup, the
power switch can be instant off or
delayed off.

Power LED

Outside of front door.

Green

Indicates AC power is supplied to
the power supply and all DC
voltages are available to the
motherboard and other devices.

Port Power LED

Outside of front door,
below the Power LED.

Green

Indicates +24 and +5 V power is
on the printer and RS232 ports.
Turning off the port switch will
cause this light to turn off after 5
or more seconds.

Battery Backup
LED

Outside of front door
below the Port Power
LED.

Blinking

Yellow

Indicates terminal is running on
battery backup when “ON.”

Reset Switch

Inside front panel door.

--

Resets terminal, all data in
memory will be lost.

Dump Switch

Inside front panel door.

--

Not used.

Port Switch

Inside front panel door

--

Default setting is “ON“(right
position). Turns on/off power to
all RS232 ports (including COM 1
& COM 2).

N/A

5VDC MB Power
LED

Behind front panel.

Amber

Indicates AC power is supplied to
the power supply and standby
voltages for motherboard are
available. Note: Do not remove
motherboard from chassis when
light is “ON” Unplug AC cord
before removing motherboard.

HDD LED
(Hard Disk Drive)

Inside front panel door.

Green

Indicates hard disk drive activity.

LAN LED

Inside front panel door.

Green

Indicates activity on the LAN
when lit

USB-IF2 & IF

Inside front panel door.

--

USB ports with +5V power
supplied when AC power light is
“ON”

Caution

: It is assumed that the user of this manual fully understands and strictly

adheres to proper Electrostatic Discharge (ESD) precautions. Failure to adhere to
precautions can cause damage to this equipment.
Always remove the power cord from the unit prior to performing any controller
maintenance.

Advertising