Hardware monitor feature setup – xl2 motherboard – FUJITSU TeamPoS 3000 XL User Manual

Page 238

Advertising
background image


TeamPoS 3000 XL and XL

2

BIOS XL

2

Motherboard

D900000145

Issue 3

10-14

10.1.15. Hardware Monitor Feature Setup – XL

2

All options are shown here, however on the BIOS screens it will be necessary to scroll down to
see all the options:

Factory Default Settings

Motherboard

Phoenix TrustedCore™ Setup Utility

Main

Advanced

Security

TPM State

Power

Boot

Exit

Hardware Monitor Feature

Item Specific Help

Hardware Monitoring

[Enabled]

CPU Temperature

35 C/095F

Alarm/Shutdown

[Shutdown]

Temperature

[90C / 194F]

PSU Temperature

30 C/086F

Alarm/Shutdown

[Shutdown]

Temperature

[70C / 158F]

System Temperature

28 C/082F

Alarm/Shutdown (High)

[Disabled]

Temperature

[65C / 149F]

Low Temperature

[Disabled]

Temperature

[5C / 41F]

FAN1 (CPU) Speed

N/A

FAN Control

[Disabled]

CPU Temperature

[80C / 176F]

System Temperature

[45C / 113F]

Alarm/Shutdown

[Disabled]

Speed

[4000RPM]

FAN2 (PSU) Speed

3068 RPM

Fan Control

[POS]

CPU Temperature

[80C / 176F]

System Temperature

[45C / 113F]

PSU Temperature

[55C / 131F]

Alarm/Shutdown

[Shutdown]

Speed

[2000RPM]

Vcore

0.928 V

+1.05V 1.040 V

+3.3V

3.424 V

+5V

5.157 V

+5V_STBY

5.103 V

+12V

11.65 V

VBAT 3.264 V

F1

Help

Select Item

-/+

Change Values

F9

Setup Defaults

Esc

Exit

Select Menu

Enter

Select Submenu

F10

Save and Exit

Advertising