Troubleshooting

D900000145

Issue 3

8-9

8.10 Deletion of Date, time and disk setup data when turning off power


No

Check item

Judgment Action

1

Is the voltage of the lithium battery on
the motherboard normal?

Y
N

Go to No.2.
Change the motherboard.

2

Is the “Clear CMOS” jumper on the
motherboard set to “normal” (jumper
between pins 2-3)

Y
N

Go to No. 3.
Set jumper correctly.

2

Is operation executed normally after
replacing the motherboard?

Y
N

End.
Change the controller.

8.11 The system fails to switch to battery backup when power failure

occurs


No

Check item

Judgment Action

1

Is the lead-acid battery connected?

Y
N

Go to No.2.
Connect the battery.

2

Is the lead-acid battery fuse blown?

Y
N

Change battery fuse.
Go to No.3.

3

Is the lead-acid battery voltage
normal?

Y

N

Go to No.4.

Recharge or replace the lead
battery.

4

Are the cables connected correctly
inside the controller?

Y
N

Go to No.5.
Connect the cable correctly.

5

Does the battery backup test function
normally?

Y
N

Check OPOS/JAVAPOS is loaded
properly.
Go to No.6.

6

Can the battery backup be activated
after replacing the backplane
assembly?

Y
N

End
No.7.

7

Can the battery backup be activated
after replacing the power supply?

Y
N

End
Go to No.8.

8

Can the battery backup be activated
after replacing the motherboard?

Y
N

End
Change the controller.