4-34

System Manual

C79000-G8576-C199-06

The filter subdrawer with fixing grid, two plug-in guide rails and the
corresponding filter mats are available as an option (see the ordering
instructions for the order numbers).

To insert a filter, you must secure the filter subdrawer to the lower side of the
power supply unit housing.

Proceed as follows:

Step

Action

1

Install the guide rails in such a way that the round tabs fit into the
corresponding openings on the lower side of the PSU.

2

Insert a filter mat in the filter subdrawer and secure it with the enclosed
fixing grid.

3

Position the filter subdrawer in the guide rails, push it back and swivel it up
so that it locks in place.

On the AC power supply units, the voltage selector switch is situated on the
front plate and marked Voltage Selector. You can select a voltage of 120 V or
230 V. The factory setting is 230 V.

Set the voltage according to your requirements

Step

Action

1

Disconnect the power supply unit from the line voltage.

2

Use a screwdriver to remove the transparent cover.

3

Set the voltage selector switch to your required voltage.

4

Refit the transparent cover.

Fitting the Filter
Subdrawer