Siemens S5-135U/155U User Manual
Page 150
Advertising

5-10
System Manual
C79000-G8576-C199-06
LEDs SI1 and SI2 indicate faults in communication via interfaces SI1
and SI2:
LED SI1
LED SI2
Cause
on
on
Communication is not possible at both interfaces.
Internal fault.
on
off
SI1:
No communication possible.
Internal fault.
SI2:
Interface is initialized and ready.
LED SI2 is always off if no interface module is
inserted.
off
on
SI1:
Interface is initialized and ready.
SI2:
No communication possible. Wrong module
inserted or internal fault.
off
off
Both interfaces are initialized and ready.
LED SI2 is always off if no interface module is
inserted.
Fault LEDs SI1
and SI2
CPUs, Memory Cards, Memory Submodules, Interface Submodules
Advertising