Id label element purpose a voltage selector – Siemens S5-135U/155U User Manual

Page 88

Advertising
background image

4-22

System Manual

C79000-G8576-C199-06

Apart from the jumpers, the LEDs and controls of the power supply unit are
fitted on the front plate. The following figure shows their locations:

6ES5955-3LF42

L1

N

1

2

3

4

5

6

7

8

9 10

11

14

12

15

13

16

17 18

+

+

+

+

AC120V4,5A
AC230V2,6A

CAUTION!
Disconnect
before
removing
power supply!

Voltage
selector

Unlock
Fan 1

Unlock
Fan2

Unlock

Fan3/Res.Batt

.

Input
DC 24V Ext.

AC line 50/60 Hz

Enable
Power supply

Voltage Monitor

Fan

Battery

Ext.Batt.

DC 4,5V

Fault

Warning

Alarm

Warning
max. AC 250V/3A

max. AC 250 V/ 3A

V

o

ltage low

Fan1

MB low

Fan2

RB low

5V

o.k.

Fan3

Reset

Alarm

EN UH

Power

I

I

1

234

5

6

7

89

10

Batt. 3,6V/5Ah

Replace by
trained personnel
only!

Use battery holder

C98100-A1155-B21
only!

SIEMENS

Output

DC 24V 2,8A

DC 5/15/24V

Internal

3V=40A

15V

o.k.

24V

o.k.

Batt.+Fan

G

D

A

H

I

F

B

C

L

K

J

M

E

The labelling and purpose of the LEDs and controls are given in the
following table:

ID

Label

Element

Purpose

A

Voltage
selector

1)

Switch

Voltage selector switch:
choice of 120 V or 230 V

B

Power

Switch

Standby On/Off switch (not system
On/Off switch)

C

Voltage low

Red LED

Low voltage at load voltage monitor input

D

Fan 1

Red LED

Failure of Fan 1

E

Fan 2

Red LED

Failure of Fan 2

F

Fan 3

Red LED

Failure of Fan 3

G

Alarm

Red LED

Indicates failure of at least two fans of
insufficient air flow

H

MB low

Yellow LED

Lithium battery/external battery voltage
below preset limit (3V)

I

RB low

Yellow LED

Rechargeable battery voltage below preset
limit (3V)

J

Reset Batt.+Fan

Pushbutton

Reset of LEDs D, E, F, G, H, I when fault
cleared

K

5V o.k.

Green LED

Lights up to indicate output voltage
within permissible range

L

15V o.k.

Green LED

Lights up to indicate output voltage
within permissible range

M

24V o.k.

Green LED

Lights up to indicate output voltage
within permissible range

1)

Only on the 6ES5 955-3LC42 and 6ES5 955-3LF42

LEDs and Controls

Central Controllers and Expansion Units Power Supply Units

Advertising