11 interface submodules – Siemens S5-135U/155U User Manual

Page 232

Advertising
background image

5-92

System Manual

C79000-G8576-C199-06

5.11

Interface Submodules

The second serial interface of the CPU 928B can be optionally used as:

S

A PG interface (for PG and operator panels)

S

An interface for the RK 512 computer link

S

An interface for data transmission with procedures 3964/3964R

S

An interface for data transmission with the “open driver”

S

An interface for data transmission via the SINEC L1 bus (from Version
6ES5 928-3UB12)

The second serial interface of the CPU 948 can be used as:

S

A PG interface (for PG and operator panels)

To use the second interface as ...

... you require ...

a PG interface

the PG submodule

an interface for data transmission
with

RK 512 computer link,
procedures 3964/3964R
or “open driver”

the V.24 (RS 232C)
or TTY
or RS 422 A/485 submodule
(only in RS 422 A mode)

an interface for data transmission
via the SINEC L1 bus

the SINEC L1 submodule

Using the Interface
Submodules

CPUs, Memory Cards, Memory Submodules, Interface Submodules

Advertising