5 a/d converter cautions – NEC uPD78P078 User Manual

Page 305

Advertising
background image

305

CHAPTER 15 A/D CONVERTER

15.5 A/D Converter Cautions

(1) Current consumption in standby mode

The A/D converter operates on the main system clock. Therefore, its operation stops in STOP mode or in

HALT mode with the subsystem clock. As a current still flows in the AV

REF0

pin at this time, this current must

be cut in order to minimize the overall system power dissipation. In Figure 15-9, the power dissipation can

be reduced by outputting a low-level signal to the output port in standby mode. However, there is no precision

to the actual AV

REF0

voltage, and therefore the conversion values themselves lack precision and can only

be used for relative comparison.

Figure 15-9. Example of Method of Reducing Current Consumption in Standby Mode

Series Resistor String

V

DD

AV

REF0

AV

REF0

AV

SS

Output Port

.

.

µ

PD78078, 78078Y

= V

DD

Advertising