CHAPTER 24 STANDBY FUNCTION

24.2.2 STOP mode

(1) STOP mode set and operating status

The STOP mode is set by executing the STOP instruction. It can be set only with the main system clock.

Cautions 1. When the STOP mode is set, the X2 pin is internally connected to V

DD

via a pull-up

resistor to minimize leakage current at the crystal oscillator. Thus, do not use the STOP

mode in a system where an external clock is used for the main system clock.

2. Because the interrupt request signal is used to release the standby mode, if there is

an interrupt source with the interrupt request flag set and the interrupt mask flag reset,

the standby mode is immediately cleared if set. Thus, the STOP mode is reset to the

HALT mode immediately after execution of the STOP instruction. After the wait set

using the oscillation stabilization time select register (OSTS), the operating mode is set.

The operating status in the STOP mode is described below.

Table 24-3. STOP Mode Operating Status

STOP Mode Setting

With Subsystem Clock

Without Subsystem Clock

Item

Clock Generator

Only main system clock stops oscillation.

CPU

Operation stops.

Port (output latch)

Status before STOP mode setting is held.

16-bit timer/event counter

Operable when watch timer output is used

Operation stops.

as count clock (f

XT

is selected as count

clock for watch timer).

8-bit timer/event counters 1 and 2

Operable when TI1 or TI2 is selected for the count clock.

8-bit timer/event counters 5 and 6

Operable when TI5 or TI6 is selected for the count clock.

Watch timer

Operable when f

XT

is selected for the count clock.

Operation stops.

Watchdog timer

Operation stops.

A/D converter

Operation stops.

D/A converter

Operable.

Real-time output port

Operable when external trigger is used, or TI1 or TI2 is selected for the 8-bit timer/

event counter 1 or 2 count clock.

Serial Interface

When a function other than auto

Operable only when externally supplied clock is specified as the serial clock.

transmit/receive & UART is used

When auto transmit/receive

Operation stops.

function or UART is used

External interrupt

INTP0

Operation disabled.

INTP1 to INTP6

Operable.

Bus lines in external expansion

AD0 to AD7

Enters high-impedance state.

A0 to A15

Holds the state before STOP mode is set.

ASTB

Outputs low level.

WR, RD

Outputs high level.

WAIT

Enters high-impedance state.