CHAPTER 18 SERIAL INTERFACE CHANNEL 0 (

µ

PD78078Y Subseries)

<6>

<5>

<4>

<3>

<2>

<1>

<0>

<7>

Symbol

SBIC

BSYE ACKD ACKE

FF61H 00H R/W

Note1

Address After Reset R/W

ACKT CMDD RELD CMDT RELT

(b) Serial bus interface control register (SBIC)

SBIC is set by a 1-bit or 8-bit memory manipulation instruction.

RESET input sets SBIC to 00H.

R/W

RELT

Use for stop condition output. When RELT = 1, SO0 latch is set to 1. After SO0 latch setting, automatically cleared to
0. Also cleared to 0 when CSIE0 = 0.

R/W

CMDT

Use for start condition output. When CMDT = 1, SO0 latch is cleared to 0. After clearing SO0 latch, automatically
cleared to 0. Also cleared to 0 when CSIE0 = 0.

R

RELD

Stop Condition Detection

0

Clear Conditions
• When transfer start instruction is executed
• If SIO0 and SVA values do not match in address reception
• When CSIE0 = 0
• When RESET input is applied

1

Setting Condition
• When stop condition is detected

R

CMDD

Start Condition Detection

0

Clear Conditions
• When transfer start instruction is executed
• When stop condition is detected
• When CSIE0 = 0
• When RESET input is applied

1

Setting Condition

• When start condition is detected

R/W

ACKT

SDA0 (SDA1) is set to low after the Set instruction execution (ACKT = 1) before the next SCL falling edge. Used for
generating an ACK signal by software if the 8-clock wait mode is selected. Cleared to 0 if CSIE = 0 when a transfer by
the serial interface is started.

R/W

ACKE

Acknowledge Signal Automatic Output Control

Note 2

0

Disabled (with ACKT enabled). Used when receiving data in the 8-clock wait mode or when transmitting data.

Note 3

1

Enabled.
After completion of transfer, acknowledge signal is output in synchronization with the 9th falling edge of SCL clock
(automatically output when ACKE = 1). However, not automatically cleared to 0 after acknowledge signal output.
Used for reception when the 9-clock wait mode is selected.

R

ACKD

Acknowledge Detection

0

Clear Conditions
• When transfer start instruction is executed
• When CSIE0 = 0
• When RESET input is applied

1

Set Conditions
• When acknowledge signal is detected at the rising edge of SCL clock after completion of transfer

R/W

BSYE

Control of N-ch Open-Drain Output for Transmission in I

2

C Bus Mode

Note 5

Note 4

0

Output enabled (transmission)

1

Output disabled (reception)

Notes 1. Bits 2, 3, and 6 (RELD, CMDD, ACKD) are read-only bits.

2. This setting must be performed prior to transfer start.

3. In the 8-clock wait mode, use ACKT for output of the acknowledge signal after normal data reception.

4. The busy mode can be released by the start of a serial interface transfer or reception of an address

signal. However, the BSYE flag is not cleared.

5. When using the wake-up function, set BSYE to 1.

Remark

CSIE0 : Bit 7 of serial operating mode register 0 (CSIM0)