CHAPTER 19 SERIAL INTERFACE CHANNEL 1

(2) Automatic transmit/receive data setting

(a) Transmit data setting

<1>

Write transmit data from the least significant address FAC0H of buffer RAM (up to FADFH at

maximum). The transmit data should be in the order from high-order address to low-order

address.

<2>

Set to the automatic data transmit/receive address pointer (ADTP) the value obtained by

subtracting 1 from the number of transmit data bytes.

(b) Automatic transmit/receive mode setting

<1>

Set CSIE1 and ATE of the serial operating mode register 1 (CSIM1) to 1.

<2>

Set RE of the automatic data transmit/receive control register (ADTC) to 1.

<3>

Set a data transmit/receive interval in the automatic data transmit/receive interval specify register

(ADTI).

<4>

Write any value to the serial I/O shift register 1 (SIO1) (transfer start trigger).

Caution Writing any value to SIO1 orders the start of automatic transmit/receive operation and

the written value has no meaning.

The following operations are automatically carried out when (a) and (b) are carried out.

• After the buffer RAM data specified with ADTP is transferred to SIO1, transmission is carried out (start

of automatic transmission/reception).

• The received data is written to the buffer RAM address specified with ADTP.

• ADTP is decremented and the next data transmission/reception is carried out. Data transmission/

reception continues until the ADTP decremental output becomes 00H and address FAC0H data is

output (end of automatic transmission/reception).

• When automatic transmission/reception is terminated, TRF is cleared to 0.