CHAPTER 18 SERIAL INTERFACE CHANNEL 0 (

µ

PD78078Y Subseries)

(6) Interrupt request signal generator

This circuit controls interrupt request signal generation. It generates interrupt request signals according to

the settings of interrupt timing specification register (SINT) bits 0 and 1 (WAT0, WAT1) and serial operation

mode register 0 (CSIM0) bit 5 (WUP), as shown in Table 18-3.

(7) Acknowledge output circuit and stop condition/start condition/acknowledge detector

These two circuits output and detect various control signals in the I

2

C mode.

These do not operate in the 3-wire serial I/O mode and 2-wire serial I/O mode.

Table 18-3. Serial Interface Channel 0 Interrupt Request Signal Generation

Serial Transfer Mode

BSYE WUP WAT1 WAT0 ACKE

Description

3-wire or 2-wire serial I/O mode

0

0

0

0

0

An interrupt request signal is generated each

time 8 serial clocks are counted.

Other than above

Setting prohibited

I

2

C bus mode (transmit)

0

0

1

0

0

An interrupt request signal is generated each time

8 serial clocks are counted (8-clock wait).

Normally, during transmission the settings WAT21,

WAT0 = 1, 0, are not used. They are used only

when wanting to coordinate receive time and

processing systematically using software. ACK

information is generated by the receiving side,

thus ACKE should be set to 0 (disable).

1

1

0

An interrupt request signal is generated each

time 9 serial clocks are counted (9-clock wait).

ACK information is generated by the receiving

side, thus ACKE should be set to 0 (disable).

Other than above

Setting prohibited

I

2

C bus mode (receive)

1

0

1

0

0

An interrupt request signal is generated each

time 8 serial clocks are counted (8-clock wait).

ACK information is output by manipulating ACKT

by software after an interrupt request signal is

generated.

1

1

0/1

An interrupt request signal is generated each

time 9 serial clocks are counted (9-clock wait).

To automatically generate ACK information,

preset ACKE to 1 before transfer start. However,

in the case of the master, set ACKE to 0

(disable) before receiving the last data.

1

1

1

1

1

After address is received, if the values of the

serial I/O shift register 0 (SI00) and the slave

address register (SVA) match and if stop condition

is detected, an interrupt request signal is generated.

To automatically generate ACK information,

preset ACKE to 1 (enable) before transfer start.

Other than above

Setting prohibited

Remark

BSYE: Bit 7 of serial bus interface control register (SBIC)

ACKE: Bit 5 of serial bus interface control register (SBIC)