NEC uPD78P078 User Manual

Page 549

Advertising
background image

549

CHAPTER 24 STANDBY FUNCTION

HALT
Instruction

RESET
Signal

Operating
Mode

Clock

Reset
Period

HALT Mode

Oscillation

Oscillation
stop

Oscillation
Stabilization
Wait Status

Operating
Mode

Oscillation

Wait

(2

17

/f

x

: 26.2 ms)

(d) Release by RESET input

As is the case with normal reset operation, a program is executed after branch to the reset vector

address.

Figure 24-3. HALT Mode Released by RESET Input

Remarks 1. f

X

: Main system clock oscillation frequency

2. Figures in parentheses apply to operation with f

X

= 5.0 MHz.

Table 24-2. Operation after HALT Mode Release

Release Source

MKxx

PRxx

IE

ISP

Operation

Maskable interrupt

0

0

0

x

Next address instruction execution

request

0

0

1

x

Interrupt service execution

0

1

0

1

Next address instruction execution

0

1

x

0

0

1

1

1

Interrupt service execution

1

x

x

x

HALT mode hold

Non-maskable interrupt

x

x

Interrupt service execution

request

Test input

0

x

x

Next address instruction execution

1

x

x

HALT mode hold

RESET input

x

x

Reset processing

x: Don’t care

Advertising