CHAPTER 19 SERIAL INTERFACE CHANNEL 1

Figure 19-19. Operation Timings when Using Busy Control Option (BUSY0 = 0)

Caution When TRF is cleared, the SO1 pin becomes low level.

Remark

CSIIF1 : Interrupt request flag

TRF

: Bit 3 of the automatic data transmit/receive control register (ADTC)

If the busy signal becomes inactive, the wait is canceled. If the sampled busy signal is inactive, sending

or receiving of the next 8 bit data begins from the fall of the next serial clock cycle.

Furthermore, the busy signal is asynchronous with the serial clock, so even if the slave side inactivates

the busy signal, it takes nearly 1 clock cycle at the most until it is sampled again. Also, it takes another

0.5 clock cycle after sampling until data transmission resumes.

Therefore, in order to definitely cancel a wait state, it is necessary for the slave side to keep the busy

signal for at least 1.5 clock cycles.

Figure 19-20 shows the timing of the busy signal and wait cancel. In this figure, an example of the case

where the busy signal becomes active when sending or receiving starts is shown.

SCK1

SO1

D7 D6 D5 D4 D3 D2 D1 D0

D7 D6 D5 D4 D3 D2 D1 D0

BUSY

CSIIF1

SI1

D7 D6 D5 D4 D3 D2 D1 D0

D7 D6 D5 D4 D3 D2 D1 D0

TRF

Busy Input Valid

Busy Input Clear

Wait