NEC uPD78P078 User Manual

Page 420

Advertising
background image

420

CHAPTER 19 SERIAL INTERFACE CHANNEL 1

(3) Automatic data transmit/receive control register (ADTC)

This register sets automatic receive enable/disable, the operating mode, strobe output enable/disable, busy

input enable/disable, and error check enable/disable, and displays automatic transmit/receive execution and

error detection.

ADTC is set with a 1-bit or 8-bit memory manipulation instruction.

RESET input sets ADTC to 00H.

Figure 19-4. Automatic Data Transmit/Receive Control Register Format

Notes 1. Bits 3 and 4 (TRF and ERR) are read-only bits.

2. The termination of automatic transmission/reception should be judged by using TRF, not CSIIF1

(interrupt request flag).

Caution When an external clock input is selected with bit 1 (CSIM11) of the serial operating mode

register 1 (CSIM1) set to 0, set STRB and BUSY1 of ADTC to 0, 0.

Remark

x: Don’t care

<6>

<5>

<4>

<3>

<2>

<1>

<0>

<7>

Symbol

ADTC

RE

ARLD ERCE ERR

TRF

STRB BUSY1 BUSY0

FF69H 00H R/W

Note 1

Address After Reset R/W

BUSY1

0

1

1

Busy Input Control

Not using busy input

Busy input enable (active high)

Busy input enable (active low)

BUSY0

x

0

1

STRB

0

1

Strobe Output Control

Strobe output disable

Strobe output enable

TRF

1

Status in Automatic Transmit/Receive Function

Note 2

Detection of termination of automatic transmission/
reception (This bit is set to 0 upon suspension of
automatic transmission/reception or when ARLD = 0.)

During automatic transmission/reception
(This bit is set to 1 when data is written to SIO1.)

R/W

R/W

R

R

ERR

0

1

Error Detection in Automatic Transmit/Receive Function

No error (Set to 0 when data is written to SIO1)

Error occurred

R/W

ARLD

0

1

Operating Mode for Automatic Transmit/Receive Function

Single operating mode

Repetitive operating mode

R/W

RE

0

1

Receive operation in Automatic Transmit/Receive Function

Receive disable

Receive enable

R/W

ERCE

0

Error Check in Automatic Transmit/Receive Function

Error check disable

Error check enable (only when BUSY1 = 1)

0

1

Advertising