Alphabetical order – IAI America PSEL User Manual

Page 106

Advertising
background image




96

Part 2 Programs

2. Alphabetical

Order

Operation type in the output field
CC: Command was executed successfully,
ZR: Operation result is zero, PE: Operation is complete,
CP: Command part has passed, TU: Time up

EQ: Operand 1 = Operand 2, NE: Operand 1

 Operand 2,

GT: Operand 1 > Operand 2, GE: Operand 1

 Operand 2,

LT: Operand 1 < Operand 2, LE: Operand 1

 Operand 2

Command Page Condition

Operand 1

Operand 2

Output

Function

A

ABPG

133

Optional Stop program number

(Stop program number)

CC

Stop other program

ACC

153

Optional Acceleration

Prohibited

CP

Set acceleration

ACHZ

222

Optional Axis number

Prohibited

CP

Declare arch-motion Z-axis

ADD

104

Optional Augend variable

Addend

ZR

Add

AND

110

Optional AND operand variable

Operand

ZR

Logical AND

ARC

189

Optional

Passing position number

End position number

PE

Move along arc

ARC2

183

Optional

Passing position number

End position number

PE

Move along arc 2

ARCC

186

Optional Center position number Center angle

PE

Move along arc via specification of center
position and center angle

ARCD

185

Optional End position number

Center angle

PE

Move along arc via specification of end position
and center angle

ARCH

222

Optional Position number

Position number

PE

Arch motion

ATN

108

Optional

Inverse-tangent
assignment operation

Operand ZR

Inverse

tangent

ATRG

226

Optional Position number

Position number

CP

Set arch trigger

AXST

199

Optional Variable number

Axis number

CP

Get axis status

B

BASE

158

Optional Reference axis number Prohibited

CP

Set reference axis

BGPA

227

Optional Palletizing number

Prohibited

CP

Declare start of palletizing setting

BGSR

129

Prohibited

Declaration subroutine
number

Prohibited CP

Start

subroutine

BTPF

119

Optional Output port, flag

Timer setting

CP

Output OFF pulse

BTPN

118

Optional Output port, flag

Timer setting

CP

Output ON pulse

BT



117

Optional Start output, flag

(End output, flag)

CP

Output, flag [ON, OF, NT]

C

CANC

161

Optional (Input port to abort)

(CANC type)

CP

Declare port to abort

CHPR

239

Optional 0 or 1

Prohibited

CP

Change task level

CHVL

184

Optional Axis pattern

Speed

CP

Change speed

CIR

188

Optional

Passing position 1 number Passing position 2 number

PE

Move along circle

CIR2

182

Optional

Passing position 1 number Passing position 2 number

PE

Move along circle 2

CLOS

206

Optional Channel number Prohibited

CP

Close

channel

CLR

103

Optional Start-of-clear variable

End-of-clear variable ZR

Clear

variable

COS

107

Optional

Cosine assignment
variable

Operand ZR

Cosine

CP



113

Optional Comparison variable Comparison

value

EQ NE GT
GE LT LE

Compare

D

DCL

154

Optional Deceleration

Prohibited CP

Set

deceleration

DEG

157

Optional Division angle

Prohibited

CP

Set division angle

DIS

163

Optional Distance

Prohibited

CP

Set spline division distance

DIV

105

Optional Dividend variable Divisor

ZR

Divide

DW



193

Optional Comparison variable

Comparison value

CP

Loop [EQ, NE, GT, GE, LT, LE]

E

ECMD 241

Optional

1

Axis number

CC

Get motor current value

ECMD 242

Optional

5

Axis number

CC

Get axis operation status

ECMD 243

Optional

20

Variable number

CC

Get parameter value

EDDO

194

Prohibited

Prohibited

Prohibited

CP

Declare end of DO

EDIF

192

Prohibited

Prohibited

Prohibited

CP

Declare end of IF

EDPA

227

Prohibited

Prohibited Prohibited

CP

Declare end of palletizing setting

EDSL

198

Prohibited

Prohibited

Prohibited

CP

Declare end of SLCT

Advertising