IAI America PSEL User Manual

Page 35

Advertising
background image




25

Part 1 Installation

[15]

Motor power connector:

This connector is used to input the 24-VDC motor power.

The power supply connected to this connector is used as the dedicated
motor drive source.
Since the controller has a built-in drive-source cutoff relay, the power
supply to the motor will be cut off internally if an emergency stop is
actuated or other abnormality occurs.

Although the motor power and control power are input independently, the
0-V terminals of both are connected inside the controller. They are also
connected to the ground for the controller’s internal power supply and are
not isolated.

Item Specification

Remarks

5.08 mm, 2-piece
COMBICON, 2 pins

MSTB2.5/2-GF-5.08 by
Phoenix Contact

Cable-end connector

MSTB2.5/2-STF-5.08 by
Phoenix Contact

Applicable wire size

AWG20 ~ 14 (0.5 ~ 2.0 sq)

Applicable
connector

Recommended
stripped-wire length

7 mm

Connector name

MP

Input voltage

24 VDC

 10%

Maximum input
current

4.0 A

2.0 A per axis

No. Name

Function

1 0

V

Motor power input ground
(Connected to the internal
ground)

Terminal
assignments

2

24 V

Motor power input +24 V




Advertising