Appendix

Axis operation type and rotational axis mode
Axis-specific parameter No. 1, “Axis operation type”

No.

Parameter name

Default value

Input range

Unit

1

Axis operation type

Varies depending on the actuator.

0 ~ 1

None



 Explanation of setting

This parameter defines the type of the actuator to be used.


 Set value

0:

Linear movement axis

Actuators other than rotational axes of multi-rotation type

1:

Rotational movement axis

Rotational axes of multi-rotation type (RCP2-RTBL,. RCP2-RTCL)


Axis-specific parameter No. 66, “Mode selection for rotational axis”

No.

Parameter name

Default value

Input range

Unit

66

Rotational axis mode selection

0

0 ~ 5

None


 Explanation of setting

Select the mode for a rotational axis.
Related parameter: Axis-specific parameter No. 7, “Soft limit +”


 Set value

0: Normal
1: Index

mode

If a rotational axis is used, this parameter will be fixed to “1.”
* When the index mode is set, the soft limit will be fixed to 359.999 mm internally.

2 ~ 5: Reserved by the system



Note: If a simplified absolute unit is used, the following settings are disabled:

 Linear movement axis:

If “0” is set, the infinite stroke mode cannot be set using
parameter No. 68.

 Rotational movement axis: If “1” is set to enable the index mode, short-cut control cannot be

selected using parameter No. 67.