IAI America PSEL User Manual
Page 400

390
Appendix
Axis operation type and rotational axis mode
Axis-specific parameter No. 1, “Axis operation type”
No.
Parameter name
Default value
Input range
Unit
1
Axis operation type
Varies depending on the actuator.
0 ~ 1
None
Explanation of setting
This parameter defines the type of the actuator to be used.
Set value
0:
Linear movement axis
Actuators other than rotational axes of multi-rotation type
1:
Rotational movement axis
Rotational axes of multi-rotation type (RCP2-RTBL,. RCP2-RTCL)
Axis-specific parameter No. 66, “Mode selection for rotational axis”
No.
Parameter name
Default value
Input range
Unit
66
Rotational axis mode selection
0
0 ~ 5
None
Explanation of setting
Select the mode for a rotational axis.
Related parameter: Axis-specific parameter No. 7, “Soft limit +”
Set value
0: Normal
1: Index
mode
If a rotational axis is used, this parameter will be fixed to “1.”
* When the index mode is set, the soft limit will be fixed to 359.999 mm internally.
2 ~ 5: Reserved by the system
Note: If a simplified absolute unit is used, the following settings are disabled:
Linear movement axis:
If “0” is set, the infinite stroke mode cannot be set using
parameter No. 68.
Rotational movement axis: If “1” is set to enable the index mode, short-cut control cannot be
selected using parameter No. 67.