I/o parameters, 1 i/o parameters, 401 appendix – IAI America PSEL User Manual

Page 411

Advertising
background image




401

Appendix

1. I/O

Parameters

1.1 I/O

Parameters

No. Parameter

name

Default value

(Reference)

Input range

Unit

Remarks

1 I/O

port

assignment

type

1

0 ~ 20

0: Fixed assignment
1: Automatic assignment (Priority: Network I/F module

 Standard

I/O; * Ports are assigned only for the installed adjoining slots,
starting from the standard I/O slot = For safety reasons)

2

Input port start number
with fixed standard I/O
assignments (I/O1)

000

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

3 Output

port

start

number with fixed
standard I/O
assignments (I/O1)

300

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

4 ~

9

For future expansion

-1

-1 ~ 599

10

Standard I/O error
monitor

1

0 ~ 5

0: Do not monitor
1: Monitor
2: Monitor (Do not monitor errors relating to 24-V I/O power source)
3: Monitor (Monitor only errors relating to 24-V I/O power source)
* Some

exceptions

apply.

* If this parameter is set to “0” (= Do not monitor) or “2” (= Do not

monitor errors relating to 24-V I/O power source), a system error will
not generate even when the 24-V I/O power source presents
abnormality. However, the actual outputs from digital I/Os will be cut
off by circuitry thereafter to protect the controller.

11 ~

13

For future expansion

1

0 ~ 5

14

Network I/F module –
Number of remote
input ports used

0

0 ~ 256

Multiple of 8

15

Network I/F module –
Number of remote
output ports used

0

0 ~ 256

Multiple of 8

16

Network I/F module –
Beginning input port
number based on fixed
assignment

-1

-1 ~ 599

0 + (Multiple of 8) (Invalid if a negative value is set)

17

Network I/F module –
Beginning output port
number based on fixed
assignment

-1

-1 ~ 599

300 + (Multiple of 8) (Invalid if a negative value is set)

18

Network I/F module
error monitor

1

0 ~ 5

0: Do not monitor, 1: Monitor
* A system error will occur if a network link error remains for the

duration of the network link error check timer value or longer (refer
to I/O Parameter No. 120).

* Some

exceptions

apply.

19 (For

expansion)

0

20

Input filtering periods

2

1 ~ 9

msec Input signal is recognized when the status is held for twice the period

set by this parameter.

21 For

future

expansion

(change prohibited)

0 1

~

9

22

For future expansion

0

0 ~ 99999

msec

23

For future expansion

0H

0H ~

FFFFFFFFH