IAI America PSEL User Manual

Page 349

Advertising
background image




339

Part 3 Positioner Mode


 Servo ON output (SVON)
This signal will turn ON when the servo turns on. Issue a movement command after the servo ON
output signal has turned ON.

 System battery error
This signal will turn ON when the voltage of the optional system-memory backup battery drops to a
specified level.