IAI America PSEL User Manual
Page 460

450
Appen
dix
(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
C8B
Circle/arc calculation logic error
The arc calculation logic is invalid.
C8D
Circle/arc calculation error
Position data that cannot be used in arc movement was specified. Check the
position data.
C8E
Point deletion error during command execution
The final point data was deleted while continuous point movement was being
calculated.
C8F
Axis operation type error
The axis operation type is invalid. Check “Axis-specific parameter No. 1, Axis
operation type” and perform operation appropriate for the operation type
specified.
C90
Spline calculation logic error
The spline processing logic is invalid.
C91
Push-motion axis multiple specification error
Two or more push-motion axes were specified.
C92
Push-motion approach distance/speed specification error
The specified push-motion approach distance/speed is invalid.
C93
System output operation error
The user attempted a system output operation (through the port specified by I/O
parameter for output function selection or the zone output port specified by
axis-specific parameter).
C94
PIO program number error
The PIO-specified program number is invalid.
C95
AUTO program number error
The setting of “Other parameter No. 1, Auto-start program number” is invalid.
C96
Start error from operation-abort program
(This error should not occur now that the specification has been changed.)
C97
Program number error for I/O processing program at
operation/program abort
The setting of “Other parameter No. 2, I/O processing program number at
operation/program abort” is invalid.
C98
Program number error for I/O processing program at operation
pause
The setting of “Other parameter No. 3, I/O processing program number at all
operation pause” is invalid.
C99
Home sensor non-detection error
The home sensor cannot be detected. Check the wiring and sensor.
C9D
Card parameter write error
Error writing card parameters
C9E
Servo calculation overflow error
Internal servo calculation error
CA1
Abnormal absolute-data backup battery voltage (Driver analysis)
Check the connection of the absolute-data backup battery/replace the battery
and/or check the encoder cable connection, and then perform an absolute reset.
CA2
Abnormal absolute-data backup battery voltage (Main analysis)
Check the connection of the absolute-data backup battery/replace the battery
and/or check the encoder cable connection, and then perform an absolute reset.
CA3
Slave setting data out-of-range error
The data set to the slave is outside the allowable range.
CA4
Slave error response
An error response was returned from the slave.
CA5
Stop deviation overflow error
Movement may have occurred during stopping due to external force or operation
may have been restricted during deceleration. This error may also generate when
jog operation is restricted (due to contact with an obstacle, contact with a
mechanical end before home return, etc.) or when wiring error, faulty encoder or
faulty motor is detected during deceleration.