(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

C8B

Circle/arc calculation logic error

The arc calculation logic is invalid.

C8D

Circle/arc calculation error

Position data that cannot be used in arc movement was specified. Check the
position data.

C8E

Point deletion error during command execution

The final point data was deleted while continuous point movement was being
calculated.

C8F

Axis operation type error

The axis operation type is invalid. Check “Axis-specific parameter No. 1, Axis
operation type” and perform operation appropriate for the operation type
specified.

C90

Spline calculation logic error

The spline processing logic is invalid.

C91

Push-motion axis multiple specification error

Two or more push-motion axes were specified.

C92

Push-motion approach distance/speed specification error

The specified push-motion approach distance/speed is invalid.

C93

System output operation error

The user attempted a system output operation (through the port specified by I/O
parameter for output function selection or the zone output port specified by
axis-specific parameter).

C94

PIO program number error

The PIO-specified program number is invalid.

C95

AUTO program number error

The setting of “Other parameter No. 1, Auto-start program number” is invalid.

C96

Start error from operation-abort program

(This error should not occur now that the specification has been changed.)

C97

Program number error for I/O processing program at
operation/program abort

The setting of “Other parameter No. 2, I/O processing program number at
operation/program abort” is invalid.

C98

Program number error for I/O processing program at operation
pause

The setting of “Other parameter No. 3, I/O processing program number at all
operation pause” is invalid.

C99

Home sensor non-detection error

The home sensor cannot be detected. Check the wiring and sensor.

C9D

Card parameter write error

Error writing card parameters

C9E

Servo calculation overflow error

Internal servo calculation error

CA1

Abnormal absolute-data backup battery voltage (Driver analysis)

Check the connection of the absolute-data backup battery/replace the battery
and/or check the encoder cable connection, and then perform an absolute reset.

CA2

Abnormal absolute-data backup battery voltage (Main analysis)

Check the connection of the absolute-data backup battery/replace the battery
and/or check the encoder cable connection, and then perform an absolute reset.

CA3

Slave setting data out-of-range error

The data set to the slave is outside the allowable range.

CA4

Slave error response

An error response was returned from the slave.

CA5

Stop deviation overflow error

Movement may have occurred during stopping due to external force or operation
may have been restricted during deceleration. This error may also generate when
jog operation is restricted (due to contact with an obstacle, contact with a
mechanical end before home return, etc.) or when wiring error, faulty encoder or
faulty motor is detected during deceleration.