(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

D5D

Fieldbus error (FBRS link error)

A FBRS link error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.

D5E

Fieldbus error (Mailbox response)

A mailbox response error was detected.
Check the status of the monitor LED on the front face of the board by referring to
the operation manual for the field network board.

D67

Motor/encoder configuration information mismatch error

The “motor/encoder configuration information” (motor identification number and
encoder identification number) in driver parameter No. 26 does not match the
“motor/ encoder configuration information” (motor identification number and
encoder identification number) in encoder parameter No. 11. Check the
parameter values, encoder cable connection, etc.

D68

No remote-mode control support board error

Hardware supporting remote-mode control is not installed, although remote-mode
control (AUTO/MANU) is specified in I/O parameter No. 79.

D69

External terminal block overcurrent or power-supply error

Overcurrent or power-supply error in the external terminal block

D70

Option use permission error

Check if any option whose use is not permitted is specified in the system
program.

D6A

Hardware unsupported function error

An attempt was made to use a function not supported by the hardware.

D6C

Actual-position soft limit over error

The actual position exceeded a soft limit by the “soft limit/actual position margin”
or more.

D6D

Logic error

A logic error occurred.

D6F

Optional password error

The optional function the controller is attempting to use requires an optional
password. Check other parameter Nos. 30 through 32, etc., in accordance with
the applicable function.