Chapter 2 specifications, Chapter 2, Specifications – IAI America PSEL User Manual

Page 24: Controller specifications

Advertising
background image




14

Part 1 Installation

Chapter 2 Specifications

1. Controller

Specifications


Base specifications of this product

Total output when maximum
number of axes are connected

30 W x 2 axes

Control power input

24 VDC

 10%

Motor power input

24 VDC

 10%

Resistance against
momentary power failure

Maximum 0.5 msec

Withstand voltage

1500 VAC for 1 minute (Measured between all power-supply terminals
and FG)

Isolation resistance

500 VDC, 10 M

 or more

Drive-source cutoff method Internal

relay

Emergency stop input

Contact B input (Internal power-supply type)

Emergency stop action

Deceleration stop + Regenerative brake by timer

Enable input

Contact B input (Internal power-supply type)

Position detection method

Incremental encoder of A/B two-phase output type

Battery

System-memory backup battery (Optional)
Lithium battery: AB-5 by IAI, 3.6 V/2000 mAh

Programming language

Super SEL language

Number of program steps

2000 steps (total)

Number of positions

1500 positions (total)

Number of programs

64 programs

Multi-tasking capability

8 programs

Storage device

Flash ROM

Data input method

Teaching pendant or PC software

PIO power input

24 VDC

 10%

Safety category

Category B (Built-in relay)

PIO inputs

24 points, NPN or PNP (Selectable as factory setting)

PIO outputs

8 points, NPN or PNP (Selectable as factory setting)

Air cooling method

Natural convection method

Weight 440

g

External dimensions

43 (W) x 159 (H) x 110 (D); mounting pitch 151 mm

Accessories

I/O flat cable
Motor power connector
Control power & system I/O connector