Chapter 2 specifications, Chapter 2, Specifications – IAI America PSEL User Manual
Page 24: Controller specifications

14
Part 1 Installation
Chapter 2 Specifications
1. Controller
Specifications
Base specifications of this product
Total output when maximum
number of axes are connected
30 W x 2 axes
Control power input
24 VDC
10%
Motor power input
24 VDC
10%
Resistance against
momentary power failure
Maximum 0.5 msec
Withstand voltage
1500 VAC for 1 minute (Measured between all power-supply terminals
and FG)
Isolation resistance
500 VDC, 10 M
or more
Drive-source cutoff method Internal
relay
Emergency stop input
Contact B input (Internal power-supply type)
Emergency stop action
Deceleration stop + Regenerative brake by timer
Enable input
Contact B input (Internal power-supply type)
Position detection method
Incremental encoder of A/B two-phase output type
Battery
System-memory backup battery (Optional)
Lithium battery: AB-5 by IAI, 3.6 V/2000 mAh
Programming language
Super SEL language
Number of program steps
2000 steps (total)
Number of positions
1500 positions (total)
Number of programs
64 programs
Multi-tasking capability
8 programs
Storage device
Flash ROM
Data input method
Teaching pendant or PC software
PIO power input
24 VDC
10%
Safety category
Category B (Built-in relay)
PIO inputs
24 points, NPN or PNP (Selectable as factory setting)
PIO outputs
8 points, NPN or PNP (Selectable as factory setting)
Air cooling method
Natural convection method
Weight 440
g
External dimensions
43 (W) x 159 (H) x 110 (D); mounting pitch 151 mm
Accessories
I/O flat cable
Motor power connector
Control power & system I/O connector