IAI America PSEL User Manual

Page 468

Advertising
background image

458

Appen

dix

(In the panel window, the three digits after “E” indicate an error number.)

Error No.

Error name

Description, action, etc.

E42

Servo job error

The servo job is invalid.

E45

Servo undefined command detection error

An undefined command was detected during servo processing.

E46

Maximum receive size over error at absolute-data acquisition

The receive size is too large when acquiring absolute data.

E47

No normal response error at absolute-data acquisition

Normal response is not received when acquiring absolute data.

E50

Driver special command ACK-timeout error

ACK cannot be detected for the driver special command.

E51

Drive unit error (DRVESR)

Error notification from the driver

E52

Encoder error (DRVESR)

Error notification from the driver

E53

Driver CPU error (DRVESR)

Error notification from the driver

E54

Servo control error (DRVESR)

Error notification from the driver

E55

Command error (DRVESR)

Error notification from the driver

E56

Motor temperature error (DRVESR)

Error notification from the driver

E58

Servo ON/OFF timeout error

Servo ON/OFF cannot be confirmed.

E59

Brake ON/OFF timeout error

Brake ON/OFF cannot be confirmed.

E5A

Pole sense non-detection error

Motor magnetic pole cannot be detected.

E5B

Detection OFF error upon pole sense completion

The motor-magnetic-pole detection status bit (Psenex) is turned OFF after
completion of pole sense.

E5C

Hold-at-stop servo job error

The servo job is invalid.

E5D

Servo packet error

The servo packets are invalid.

E5E

Servo-control-right management array number error

The servo-control-right management array number is invalid.

E5F

Length conversion parameter error

Check axis-specific parameter Nos. 47, 50, 51, 42, 1, etc.

E60

Slave maximum receive size over error

The slave receive size is too large.

E61

Slave no normal response reception error

Normal response cannot be received from the slave.

E62

Sending-slave CPU type error

The CPU type of the sending slave is invalid.

E63

Message-buffer information type error

The message-buffer information type is invalid.

E64

Abnormal standby power detection error

Abnormal standby power was detected.

E65

Regenerative resistance temperature error

A regenerative resistance temperature error was detected.

E66

AC-power overvoltage error

An AC-power overvoltage error was detected.

E67

Motor-power overvoltage error

A motor-power overvoltage error was detected.

E68

Emergency-stop status requiring reset recovery (not error)

Reset the emergency stop and then reconnect the power.

E69

Abnormal 24-V I/O power source

The 24-V I/O power source is abnormal.

E6A

Safety-gate open status requiring reset recovery (not error)

Close the safety gate and then reconnect the power.

E6B

Shutdown factor indeterminable error

Shutdown factor cannot be determined.