(In the panel window, the three digits after “E” indicate an error number.)
Error No.
Error name
Description, action, etc.
E42
Servo job error
The servo job is invalid.
E45
Servo undefined command detection error
An undefined command was detected during servo processing.
E46
Maximum receive size over error at absolute-data acquisition
The receive size is too large when acquiring absolute data.
E47
No normal response error at absolute-data acquisition
Normal response is not received when acquiring absolute data.
E50
Driver special command ACK-timeout error
ACK cannot be detected for the driver special command.
E51
Drive unit error (DRVESR)
Error notification from the driver
E52
Encoder error (DRVESR)
Error notification from the driver
E53
Driver CPU error (DRVESR)
Error notification from the driver
E54
Servo control error (DRVESR)
Error notification from the driver
E55
Command error (DRVESR)
Error notification from the driver
E56
Motor temperature error (DRVESR)
Error notification from the driver
E58
Servo ON/OFF timeout error
Servo ON/OFF cannot be confirmed.
E59
Brake ON/OFF timeout error
Brake ON/OFF cannot be confirmed.
E5A
Pole sense non-detection error
Motor magnetic pole cannot be detected.
E5B
Detection OFF error upon pole sense completion
The motor-magnetic-pole detection status bit (Psenex) is turned OFF after
completion of pole sense.
E5C
Hold-at-stop servo job error
The servo job is invalid.
E5D
Servo packet error
The servo packets are invalid.
E5E
Servo-control-right management array number error
The servo-control-right management array number is invalid.
E5F
Length conversion parameter error
Check axis-specific parameter Nos. 47, 50, 51, 42, 1, etc.
E60
Slave maximum receive size over error
The slave receive size is too large.
E61
Slave no normal response reception error
Normal response cannot be received from the slave.
E62
Sending-slave CPU type error
The CPU type of the sending slave is invalid.
E63
Message-buffer information type error
The message-buffer information type is invalid.
E64
Abnormal standby power detection error
Abnormal standby power was detected.
E65
Regenerative resistance temperature error
A regenerative resistance temperature error was detected.
E66
AC-power overvoltage error
An AC-power overvoltage error was detected.
E67
Motor-power overvoltage error
A motor-power overvoltage error was detected.
E68
Emergency-stop status requiring reset recovery (not error)
Reset the emergency stop and then reconnect the power.
E69
Abnormal 24-V I/O power source
The 24-V I/O power source is abnormal.
E6A
Safety-gate open status requiring reset recovery (not error)
Close the safety gate and then reconnect the power.
E6B
Shutdown factor indeterminable error
Shutdown factor cannot be determined.