*Supplement

134

Supplement

Write the data to Flash ROM.

Press the F1 (Yes) key.

Restart the controller.

Press the F1 (Yes) key.

(7) Display the current positions on the teaching screen.
After turning the servo ON, execute action check by jogging. (Master axis operation)
Mode Transition:

To switch the current position screen to the input

data screen, press the F3 (Disp) key.

To turn the servo ON/OFF, use the ON/OFF key.

If the error No. D0A driver overload error, error No. C6B deviation overflow error, error No. CA5
stop deviation overflow error, etc., occurs, check the following items:

ƒ If the current position of the master axis is greatly different from that of the slave axis, setting

in (5) may be wrong.

ƒ Confirm that there are no input errors or change omissions as for the parameters below.

“Each-axis parameter No. 65 synchro other axis No.”
“Each-axis parameter No. 83 ABS synchro slave axis coordinate initialization cancel”

ƒ Confirm that slider actions are not restrained.

&  @,;B@8B

In the case of “each-axis parameter No. 38 encoder ABS/INC type:” master axis = 1 and slave
axis = 0:
After “2. Location Adjustment of Synchro Axes Sliders,” execute a normal absolute reset only for
the master axis.
For the operating method, refer to the Teaching Pendant Instruction Manual.

Note: The synchro axis for which the standard procedure absolute reset has been executed does

not have the function of correcting the slider displacement during power OFF after the
servo is turned ON.