8. How to Save Data

24

 2@D@ C/

Since the X-SEL Controller adopts flash memory, there is a storage area by battery backup and a
storage area by flash memory according to the data to be stored.
In addition, even if data is transferred from the PC software or Teaching Pendant, the data is only
to be written in memory as shown in the chart below and the data is erased by power-off or
controller reset.
To ensure data storage, write the data you want to store in flash memory.

#

 ?D FB??@F->-F

(Other parameter No. 20=2 (System memory backup battery equipped))

Edit data with PC or

Teaching Pendant

Save the data during the

power is on and delete

the data by reset

Save data even after the power OFF

Flash write

Program

parameter

(content 1)

Symbol

Flash

memory

Memory

Transmit

Reset read

Transmit

Slave card

parameter

(content 2)

Memory

Transmit

Reset read

Transmit

* Encoder

parameter

Memory

* Encoder

Transmit

Reset read

Position

Battery

backup

memory

Flash

memory

Transmit

Flash write

Battery

backup

memory

SEL global data

(content 3)

Error list

Transmit

* Encoder parameters are not stored within the controller but in the EEPROM of the actuator’s

encoder itself. They are read into the controller at power-on or software-reset time.