13. Symbol Edit

86

#$( 0B8 :

The edit data will be cleared by restoring the power and executing software reset, only if the
program edit data was transmitted to the controller.
To save the data after restoring the power and executing software reset, write the data to Flash
ROM.
From the final editing screen, return to the Flash ROM writing screen with the ESC key.

To write the data to Flash ROM, press the F1 (Yes)

key.

If not, press the F2 (No) key.

During Flash ROM writing, “Please Wait....” blinks.

 6C B @<<  @D @  @@

0B8 D

Flash ROM writing is complete.

Return to the edit screen with the ESC key.

87

#% F?;@

Symbol (Names) can be applied to variables, input ports, flags, points, etc., in X-SEL controller.

Select the F1 (Edit) key.

Select the F3 (Sym) key.

#%# F?;@3?B

Symbolized items will be displayed in the function

key area. Each time by pressing SF key, items are

shifted and displayed.

F?;@3?B

Cnst: Constant number
Var: Variable
Prog: Program No.
Posi: Position No.

In:

Input port No.

Out: Output port No.
Flag: Flag No.
Axis: Axis No.

Tag: Tag No.
SubR: Subroutine No.

Aclr: All clear

Clear all the symbol data.

Display the list of items to symbolize by using the

SF(shift) key and select with the function keys.

Advertising