2.2 ASCII Output

Output of System Recognition Status (CF)

• Output using the CF command.
• Regardless of the base unit type, 6 slots of module information is always output.

Syntax

EACRLF
n_S=aaa-bbb-ccc_R=aaa-bbb-ccc_mmm...mCRLF
n_S=aaa-bbb-ccc_R=aaa-bbb-ccc_mmm...mCRLF
n_S=aaa-bbb-ccc_R=aaa-bbb-ccc_mmm...mCRLF
n_S=aaa-bbb-ccc_R=aaa-bbb-ccc_mmm...mCRLF
n_S=aaa-bbb-ccc_R=aaa-bbb-ccc_mmm...mCRLF
n_S=aaa-bbb-ccc_R=aaa-bbb-ccc_mmm...mCRLF
ENCRLF

n

Module number (0 to 5)

S=

Status of modules set on the system

R=

Status of modules actually installed

aaa:

Module model

bbb:

Module basic specifications code (input/output type)

ccc:

Module basic specifications code (measuring interval, no. of channels)

mmm...m Module error status (10 characters)

RomError:

EEPROM damaged

CalError:

Calibration value damaged

SlotError:

30-CH Medium Speed DCV/TC/DI Input Module installed in
invalid slot.

_

Blank: Normalize without error

Example

EA
0 S=MX110-UNV-H04 R=MX110-UNV-H04
1 S=MX110-UNV-M10 R=MX110-UNV-M10 CalError
2 S=MX110-UNV-M10 R=MX110-UNV-H04
3 S=MX115-D05-H10 R=MX115-D05-H10
4 S=MX125-MKC-M10 R=-------------
5 S=------------- R=-------------
EN