102

Pre-series version

BU 0180 GB-0914

Value Function

Description

Signal

30

Disable PID

Switching the PID controller / process controller function on and
off (high = ON)

High

31

2

Disable right rotation

Blocks the >Enable right/left< via a digital input or Bus control.
Does not depend on the actual direction of rotation of the motor
(e.g. following negated setpoint).

Low

32

2

Disable left rotation

Low

33

... 44 reserved

45

3-W-Ctrl. Start-Right

“3-Wire-Control Start-Right”

(Closing button)

This control function provides an alternative to enable R/L (01/02),
in which a permanently applied level is required.

Here, only a control impulse is required to trigger the function.
The control of the FI can therefore be performed entirely with
buttons.

0

1

Flank

46

3-W-Ctrl Start-Left

“3-Wire-Control Start-Left”

(Closing button)

0

1

Flank

49

3-Wire-Ctrl. Stop

“3-Wire-Control Stop”

(Opening button)

10

Flank

47

Motorpot. Freq.

+

"

Motor potentiometer frequency +"

In combination with enable R/L the output frequency can be
continuously varied. To save a current value in P113, both inputs
must be at a High voltage for 0.5s. This value then applies as the
next starting value for the same direction of rotation (Enable R/L)
otherwise start at f

MIN

.

High

48

Motorpot.Freq.

-

Motor potentiometer frequency -

High

50

Bit 0 fixed frequency array

Binary coded digital inputs to generate up to 32 fixed frequencies.
(P465: [-01] ... [-15])

High

51

Bit 1 fixed frequency array

High

52

Bit 2 fixed frequency array

High

53

Bit 3 fixed frequency array

High

55

... 64 Reserved

65

2

Man/auto release brake

"Release brake manually/
automatically"

The brake is automatically released by the frequency inverter
(automatic brake control) if this digital input has been set.

High

66

2

Man. release brake

"Release brake manually"

The brake is only released of the digital input is set.

High

67

Dig.out. man/auto set

"Set digital output manually /
automatically"

Set digital output 1 manually, or via the function set in (P434)

High

68

Dig.out. man. set

"Set digital output manually"

Set digital output 1 manually

High

69

Speed meas. with ini.

"Speed measurement with
initiator"

Simple speed measurement (impulse measurement) with initiator

Impulse

70

Evacuation run

"Activate evacuation run"

Setting without function

-

71

Motorpot.F+ and Save

"Motor potentiometer function

Frequency + with automatic
saving“

With this "motor potentiometer function" a setpoint value (sum) is
set via the digital inputs, and simultaneously stored. With control
enabling R/L this is then started up in the correspondingly
enabled direction. On change of direction the frequency is
retained.
Simultaneous activation of the +/- function causes the frequency
setpoint value to be set to zero.
The frequency setpoint value can also be displayed or set in the
operating value display (P001=30, current setpoint MP-

S‘) or in

P718.
Any minimum frequency set (P104) is still effective. Other setpoint
values, e.g. analog or fixed frequencies can be added or
subtracted.
The adjustment of the frequency setpoint value is performed with
the ramps from P102/103.

High

72

Motorpot.F- and Save

"Motor potentiometer function

Frequency - with automatic
saving“

High

73 ²

Right block+ Fast

"Block right rotation + emergency
stop“

As for setting 31, however coupled to the function "Fast Stop".

Low