4 option slots in the device – NORD Drivesystems BU0180 User Manual

Page 22

Advertising
background image

SK 180E Manual for frequency inverters

22

Pre-series version

BU 0180 GB-0914

2.1.4

Option slots in the device

Size 1:

Size 2:

The above drawings indicates the different installation locations for optional modules. Option slot 1 is used
for the mounting of an internal customer interface (e.g. bus module). Option location 2 for installing an
internal brake resistor is only present in size 2. The brake resistor may only be installed at the factory
and must therefore be taken into account in the order.
External bus modules, 24 V power supplies can
be implemented at option locations 3L or 3R. Option locations 4 and 5 are used for the installation of M12
sockets or plug connectors or for cable glands. Only one option per option location is possible.

Option
location

Position Meaning

Size

Sizes 1 - 2

Comments

1

Internal

Mounting location for customer units SK CU4-

2

Internal

Installation location for internal brake resistor

Only for size 2

3*

on side

Mounting location for

external technology units SK TU4-

Power plug connector (e.g. HARTING)

3 A/B*

on side

Cable gland

M25

Not available if loca-
tion 3 is occupied or
SK TU4-

… is fitted.

4 *,

5 *

on side

Cable gland

M16

Not available if
SK TU4-

… is fitted.

* R and L (right and left side)

– for motor installation: viewed from the fan wheel toward the motor shaft

3BR 3AR

3R

4R

5R

1

4L

5L

3AL

3BL

3L

1

3BR 3AR

3R

4R

5R

1

4L

5L

3AL

3BL

3L

1

2

2

Advertising