3 100hz characteristic curve (only 400v devices) – NORD Drivesystems BU0180 User Manual

Page 175

Advertising
background image

9 Additional Information

BU 0180 GB-0914

Pre-series version

175

9.8.3

100Hz characteristic curve (only 400 V devices)

( Variation 01:20:00)

An operating point 100 Hz/400 V can be selected
for a greater speed adjustment range with up to a
ratio of 1:20. Special motor data are required (see
below) that differ from the normal 50 Hz data. It
must be ensured in this case that a constant torque
is generated across the entire adjustment range
but that it is smaller than the nominal torque for 50
Hz operation.

The advantage, in addition to the greater speed
adjustment

range,

is

the

improved

motor

temperature behaviour. An external fan is not
absolutely essential for smaller output speed
ranges.

The following data refer to a 230/400 V motor
winding. They apply for IE1 or IE2 motors. It should be noted that these details may deviate slightly, as
motors are subject to certain manufacturing tolerances. It is recommended that the resistance of the
connected motor is measured by the frequency inverter (P208 / P220).

Frequency inverter type

Parameterisation data of frequency inverter

F

N

[Hz]

n

N

[min

-1

]

I

N

[A]

U

N

[V] P

N

[kW] cos

Circuit

R

St

[

]

IE1 Motors

SK…63S/4 SK 1x0E-250-340-B

100

2880

0.95

400

0.25

0.63

Delta

47.37

SK…71S/4 SK 1x0E-370-340-B

100

2895

1.07

400

0.37

0.71

Delta

39.90

SK…71L/4 SK 1x0E-550-340-B

100

2900

1.59

400

0.55

0.72

Delta

22.85

SK…80S/4 SK 1x0E-750-340-B

100

2910

2.0

400

0.75

0.72

Delta

15.79

SK…80L/4 SK 1x0E-111-340-B

100

2910

2.8

400

1.1

0.74

Delta

10.49

SK…90S/4 SK 1x0E-151-340-B

100

2925

3.75

400

1.5

0.76

Delta

6.41

SK…90L/4 SK 1x0E-221-340-B

100

2920

4.96

400

2.2

0.82

Delta

3.99

IE2 Motor

SK…80SH/4SK 1x0E-750-340-B

100

2930

1.9

400

0.75

0.70

Delta

9.34

SK…80LH/4 SK 1x0E-111-340-B

100

2920

2.56

400

1.1

0.73

Delta

6.30

SK…90SH/4SK 1x0E-151-340-B

100

2930

3.53

400

1.5

0.79

Delta

4.96

SK…90LH/4 SK 1x0E-221-340-B

100

2925

4.98

400

2.2

0.79

Delta

3.27

Frequency inverter type

Performance data at rated point*

P

B

[kW]

n

B

[min

-1

]

M

B

[Nm]

SK…63S/4 SK 1x0E-250-340-B

0.25

2840

0.90

SK…71S/4 SK 1x0E-370-340-B

0.37

2855

1.23

SK…71L/4 SK 1x0E-550-340-B

0.55

2860

1.83

SK…80S(H)/4 SK 1x0E-750-340-B

0.75

2885 (2905)

2.48 (2.4)

SK…80L(H)/4 SK 1x0E-111-340-B

1.1

2900 (2905)

3.62 (3.6)

SK…90S(H)/4 SK 1x0E-151-340-B

1.5

2925 (2925)

4.90 (4.8)

SK…90L(H)/4 SK 1x0E-221-340-B

2.2

2920 (2925)

7.20 (7.1)

* Values in brackets apply for IE2 motors

Kennlinie 100 Hz (4-poliger Motor)

0

0,2

0,4

0,6

0,8

1

1,2

0

10

20

30

40

50

60

70

80

90

100

Frequenz / Hz

M/Mn

M/M

N

P/P

N


0

1445

2890

Frequency

[Hz]
Speed

[1/min]

100 Hz characteristic curve (4-pole motor)

Advertising