NORD Drivesystems BU0180 User Manual

Page 59

Advertising
background image

3 Options

BU 0180 GB-0914

Pre-series version

59

3.3.4

Direction selection switch and potentiometer SK TIE4-SWT and SK TIE4-POT

The digital signals R and L of the direction selector switch SK TIE4-SWT (Part No.: 275274701) can be
applied directly to the corresponding digital inputs 1 and 2 of the frequency inverter.

The potentiometer (0-10 V) SK TIE4-POT (Part No.: 275274700) can be evaluated via the analog inputs of
the frequency inverter or the I/O extension. Each of the modules (control element) is supplied with a
pre-assembled cable. This must be plugged into the connection plug of the relevant module. The open ends
of the cable set must be wired to the terminal bar of the frequency inverter according to the table.

Both modules have protection class IP66.

Module

SK TIE4-SWT

Function

SK 1x0E

Color

FI

brown

24 V-supply voltage

43

Rotary switch
L - OFF - R

black

Enable R (e.g. DIN1)

21

white

Enable L (e.g. DIN2)

22

Module

SK TIE4-POT

white

Access to AIN +

14

Potentiometer
10kΩ

brown

Reference voltage 10 V

11

blue

Analog ground AGND

12

For examples of connections to the frequency inverter, please refer to Section 3.3.1.

Installation
Installation of the potentiometer (SK TIE4-POT) is possible on a 4 M25 versions of the device. In contrast,
installation of the switch (SK TIE-SWT) is only possible on the M25 holes 3BL and 3 BR; for Size 2 also
on 3AL: