8 technical data – NORD Drivesystems BU0180 User Manual

Page 151

Advertising
background image

8 Technical data

BU 0180 GB-0914

Pre-series version

151

8 Technical data

8.1 General data for frequency inverter series SK 1x0E

Function

Specification

Output frequency

0.0 … 400.0 Hz

Pulse frequency

3.0 … 16.0 kHz, standard setting = 6 kHz
Power reduction > 8 kHz for 115/230V device, >6 kHz for 400 V device.

Typical overload capacity

150% for 60 s, 200% for 3.5 s

Protection measures against

Overtemperature of the frequency inverter,
overvoltage and undervoltage

Short-circuit, earthing fault,
overload, idling

Regulation and control

Sensorless current vector control (ISD), linear V/f characteristic curve,
automatic flux adaptation (energy-saving function)

Motor temperature monitoring

I

2

t motor, PTC / Bimetal switch

Digital input

3x low 0-5 V, high 14-30 V, R

i

= 9.5 k

, C

i

= 10 nF, cycle time = 4 ms

Electrical isolation

Control terminals

Control outputs

digital output: 24V±25% DC, max. 20mA, max. 1.2k

Load

Interfaces

Standard: RS 485 (USS)

– only for

Parameter boxes

RS 232 (Single Slave)
System bus

Option: Profibus, CANopen,

DeviceNet, AS-Interface,
EtherCAT, PROFINET,
POWERLINK,
Ethernet/IP

Efficiency of frequency inverter

> 95% according to size

Storage and transport temperature

-

25°C … +60/70°C

Operating / ambient temperature

-

25°C … +50°C, according to operating mode (Details: Section 8.2)

ATEX: -

20…+40°C (Details: Section 2.10)

Long-term storage

See Section 9.11.1

Protection class

IP55, optional IP66

Max. installation altitude above sea
level

Up to 1000 m: No power reduction

1000...4000 m: 1%/ 100 m power reduction (up to 2000m overvoltage cat. 3)

2000...4000 m: Only overvoltage category 2 is maintained, external

overvoltage protection at the mains input is necessary

Ambient conditions

Transport (IEC 60721-3-2):

Vibration: 2M2

Operation (IEC 60721-3-3):

Vibration: 3M7;

Climate: 3K3 (IP55)

/ 3K4 (IP66)

Waiting time between
two mains switching cycles

60 sec for all devices in normal operating cycle

Mains/motor/brake resistance

4mm

2

flexible cable with wire end sleeves,

6mm

2

with rigid cable

Terminal screw
tightening torque
0.5...0.6 Nm

Control unit /System bus

1.5mm

2

, rigid and flexible cable with wire end

sleeves, 0.75mm² flexible cable with wire end sleeves
with plastic sleeves

RS485 / RS232

1x RJ12 (6-pin)

24V - Output
(Terminal 43)

Digital outputs

24 V DC ± 25%, max. 150 mA

3

24 V DC ± 25%, max. 20 mA

3

The current which is drawn from the digital outputs must also be covered by this. Any control modules which are

connected to the RJ12 socket also place a load on the 24V supply. (150mA = I

DIG1

+ I

DIG2

+ I

OUT

+ I

CONTROL

)

Advertising