SK 180E Manual for frequency inverters

46

Pre-series version

BU 0180 GB-0914

Wire colors on the

potentiometer

Designation

Terminal SK CU4-24V*

Terminal SK CU4-IOE

Terminal SK 1x0E

red

+10V reference

[11]

[11]

[11]

black

AGND / 0V

[12]

[12]

[12] / [40]

green

Analog input

[14]

[14] / [16]

[14] / [16]

2.10.2.3 Hand-held Technology Units for ATEX Zone 22 3D

All hand-held technology units are not approved for continuous use in the ATEX Zone 22 3D. They may
therefore only be used during commissioning or for maintenance purposes, if it is ensured that no explosive
dust atmosphere exists.

Designation

Part Number

Approved for

ATEX Zone 22 3D

Not approved for

ATEX Zone 22 3D

SK CSX-3H

275281013

x

SK PAR-3H

275281014

x

ATTENTION

The diagnostic opening of the basic unit for the connection of a hand-held
technology unit or a PC must not be opened in an atmosphere containing
explosive dust.

2.10.2.4 Braking resistors

External braking resistors of type SK BRE4-x-xxx-xxx are not permitted for use in ATEX Zone 22 3D.

Designation

Part Number

Approved for

ATEX Zone 22 3D

Not approved for

ATEX Zone 22 3D

SK BRI4-1-200-100

275272008

x

SK BRI4-1-400-100

275272012

x

SK BRE4-1-100-100

275273005

x

SK BRE4-1-200-100

275273008

x

ATTENTION

If an internal braking resistor of type SK BRI4-x-xxx-xxx is used, the power limitation for
this must be activated under all circumstances. This is achieved via parameters (P555),
(P556) and (P557) with the appropriate values. Only the resistors assigned to the rele-
vant inverter type may be used.

Advertising