2.10.2.1 Technology Units for ATEX Zone 22 3D

Designation

Part Number

Approved for

ATEX Zone 22 3D

Not approved for

ATEX Zone 22 3D

SK TI4-TU-BUS(-C)

275280000 / (275280500)

x

SK TI4-TU-NET(-C)*

275280100 / (275280600)

x

SK TU4-PBR(-C)

275281100 / (275281150)

x

SK TU4-CAO(-C)

275281101 / (275281151)

x

SK TU4-DEV(-C)

275281102 / (275281152)

x

SK TU4-IOE(-C)

275281106 / (275281156)

x

SK TU4-PBR-M12(-C)

275281200 / (275281250)

x

SK TU4-CAO-M12(-C)

275281201 / (275281251)

x

SK TU4-DEV-M12(-C)

275281202 / (275281252)

x

SK TU4-IOE-M12(-C)

275281206 / (275281206)

X

SK TU4-PNT(-C)

275281115 / (275281165)

x

SK TU4-ECT(-C)

275281117 / (275281167)

x

SK TU4-POL(-C)

275281118 / (275281168)

x

SK TU4-EIP(-C)

275281119 / (275281169)

x

2.10.2.2 Customer Units for ATEX Zone 22 3D

Designation

Part Number

Approved for

ATEX Zone 22 3D

Not approved for

ATEX Zone 22 3D

SK CU4-PBR

275271000

x

SK CU4-CAO

275271001

x

SK CU4-DEV

275271002

x

SK CU4-PNT

275271015

x

SK CU4-ECT

275271017

x

SK CU4-POL

275271018

x

SK CU4-EIP

275271019

x

SK CU4-IOE

275271006

x

SK CU4-POT

275271207

x

SK ATX-POT

275142000

x

The Category 3D frequency inverter can be equipped with an ATEX-compliant potentiometer, which can be
used to adjust a setpoint (e.g. speed) on the device. The potentiometer is used with an M20-M25 extension
in one of the M25 cable glands. The selected setpoint can be adjusted with a screwdriver. Due to the re-
movable screw closing cap, this component complies with ATEX requirements. Permanent operation may
only be carried out with the cap closed.

Frequency setpoint setting

with a screwdriver

Resistance of the potentiometer 10 kOhm