6 Parameterisation

BU 0180 GB-0914

Pre-series version

129

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P709

[-01]

...

[-07]

Voltage analog input

(Voltage of analog input)

-100.0 ... 100.0 %

Displays the measured analog input value.

[-01] = Analog input 1, Function of analog input 1 integrated into the FI

[-02] = Analog input 2, Function of analog input 2 integrated into the FI

[-03] = Ext. Analog input 1,

AIN1 of the first I/O extension (SK xU4-IOE)

[-04] = Ext. Analog input 2,

AIN2 of the first I/O extension (SK xU4-IOE)

[-05] = Ext.

A.in

1 2nd IOE,

AIN1 of the second I/O extension (SK xU4-IOE)

[-06] = Ext.

A.in

2 2nd IOE,

AIN2 of the second I/O extension (SK xU4-IOE)

[-07] = Setpoint module

P710

[-01]

[-02]

Analog output voltage

(Analog output voltage)

0.0 ... 10.0 V

Displays the delivered value of analog output.

[-01] =

First IOE,

AOUT of the first I/O extension (SK xU4-IOE)

[-02] =

Second IOE,

AOUT of the second I/O extension (SK xU4-IOE)

P711

State of relays

(State of digital output)

00000 ... 11111

(bin)

or

00 ... FF

(hex)

Indicates the actual status of the digital outputs of the frequency inverter.

Bit 0 = Digital output 1
Bit 1 = Digital output 2
Bit 2 = reserved
Bit 3 = reserved

Bit 4 = Digital output 1, IO extension 1
Bit 5 = Digital output 2, IO extension 1
Bit 6 = Digital output 1, IO extension 2
Bit 7 = Digital output 2, IO extension 2

Bits 7-4

Bits 3-0

Minimum value

0000

0

0000

0

Binary

hex

Maximum value

1111

F

0011

3

Binary

hex

SimpleBox: The binary bits are converted to a hexadecimal value and displayed.

ParameterBox: The bits are displayed with increasing values from right to left (binary).

P714

Operating time

(Operating time)

0.00 ... ___ h

This parameter shows the time for which the FI was connected to the mains and was ready for
operation.