Nord frequency inverters – NORD Drivesystems BU0180 User Manual

Page 2

Advertising
background image

SK 180E Manual for frequency inverters

About this document

2

BU 0180 GB-0914

NORD frequency inverters

Safety and operating instructions for

drive power converters

(as per: Low Voltage Directive 2006/95/EEC)

1.General

During operation, drive power converters may, depending on their
protection class, have live, bare, moving or rotating parts or hot
surfaces.

Unauthorised removal of covers, improper use, incorrect installation
or operation causes a risk of serious personal injury or material
damage.

Further information can be found in this documentation.

All transportation, installation, initialisation and maintenance work
must be carried out by qualified personnel (compliant with IEC
364, CENELEC HD 384, DIN VDE 0100, IEC 664 or DIN VDE 0110,
and national accident prevention regulations).

For the purposes of these basic safety instructions, qualified
personnel are persons who are familiar with the assembly,
installation, commissioning and operation of this product and who
have the relevant qualifications for their work.

2. Proper use in Europe

Drive power converters are components intended for installation in
electrical systems or machines.

When installed in machines, the drive power converter cannot be
commissioned (i.e. commencement of the proper use) until it has
been ensured that the machine meets the provisions of the EC
Directive 2006/42/EEC (Machine Directive); EN 60204 must also be
complied with.

Commissioning (i.e. implementation of the proper use) is only
permitted if the EMC directive (2004/108/EEC) is complied with.

Drive power converters with a CE label meet the requirements of the
Low Voltage Directive 2006/95/EEC. The stated harmonized
standards for drive current inverters are used in the declaration of
conformity.

Technical data and information for connection conditions can be
found on the rating plate and in the documentation, and must be
complied with.

The drive power converters may only be used for safety functions
which are described and explicitly approved.

3. Transport, storage

Information regarding transport, storage and correct handling must
be complied with.

4. Installation

The installation and cooling of the equipment must be implemented
according to the regulations in the corresponding documentation.

The drive power converters must be protected against
impermissible loads. Especially during transport and
handling, components must not be deformed and/or
insulation distances must not be changed. Touching of
electronic components and contacts must be avoided.

Drive power converters have electrostatically sensitive
components, which can be easily damaged by incorrect
handling. Electrical components must not be mechanically
damaged or destroyed (this may cause a health hazard!).

5. Electrical connection

When working on live drive power converters, the applicable
national accident prevention regulations must be complied
with (e.g. BGV A3, formerly VBG 4).

The electrical installation must be implemented according to
the applicable regulations (e.g. cable cross-section, fuses,
earth lead connections). Further instructions can be found in
the documentation.

Information regarding EMC-compliant installation

– such as

shielding, earthing, location of filters and installation of
cables

– can be found in the drive power converter

documentation. These instructions must be complied with
even with CE marked drive power converters. Compliance
with the limit values specified in the EMC regulations is the
responsibility of the manufacturer of the system or machine.

6. Operation

Systems in which drive power converters are installed must
be equipped, where necessary, with additional monitoring
and protective equipment as per the applicable safety
requirements,

e.g.

legislation

concerning

technical

equipment, accident prevention regulations, etc.

The parameterisation and configuration of the drive power
converter must be selected so that no hazards can occur.

All covers must be kept closed during operation.

7. Maintenance and repairs

After the drive power converter is disconnected from the
power supply, live equipment components and power
connections should not be touched immediately, because of
possible charged capacitors. Observe the applicable
information signs located on the drive power converter.

Further information can be found in this documentation.

These safety instructions must be kept in a safe place!

Advertising