4 electrical data br, Electrical data br – NORD Drivesystems BU0180 User Manual

Page 27

Advertising
background image

2 Assembly and installation

BU 0180 GB-0914

Pre-series version

27

2.3.4

Electrical data BR

Internal

Inverter ID

SK 1x0E-

Resistor type
(IP54)

Resistance

Max. continuous
output / limit**

(P

n

)

Energy
consumption*

(P

max

)

Connecting cable
or terminals

750…111-323-A

SK BRI4-1-200-100

Part. No. 275272008

200

100 W / 25%

1.0 kWs

Silicone
conductor

2x 0.75 mm

2

approx. 275 mm

151…221-340-A

SK BRI4-1-400-100

Part. No. 275272012

400

100 W / 25%

1.0 kWs

*) Maximum once within 10 s**

**) In order to prevent impermissible heating of the device, the continuous power is limited

to 1/4 of the rated power of the brake resistor.

This also has a limiting effect on the power consumption.

External

Inverter ID

SK 1x0E-

Resistor type
(IP67)

Resistance

Max. continuous
power

(P

n

)

Energy
consumption*

(P

max

)

Connecting cable
or terminals

750…111-323-A

SK BRE4-1-100-100

Part. No. 275273005

100

100 W

2.2 kWs

FEP flex

3x 1.9 mm

2

AWG 14/19

approx. 350 mm

151…221-340-A

SK BRE4-1-200-100

Part. No. 275273008

200

100 W

2.2 kWs

*)Maximum once within 120 s

Advertising