NORD Drivesystems BU0180 User Manual

Page 135

Advertising
background image

6 Parameterisation

BU 0180 GB-0914

Pre-series version

135

Parameter

Setting value / Description / Note

Device

Supervisor

Parameter
set

P750

Overcurrent statistic

(Overcurrent statistic)

S

0 ... 9999

Number of overcurrent messages during the operating period P714.

P751

Stat. Overvoltage

(Overvoltage statistic)

S

0 ... 9999

Number of overvoltage messages during the operating period P714.

P752

Stat. mains failure

(Mains failure statistics)

S

0 ... 9999

Number of mains faults during the operating period P714.

P753

Stat. overtemperature

(Overheating statistics)

S

0 ... 9999

Number of overtemperature faults during the operating period P714.

P754

Stat. parameter lost

(Parameter loss statistic)

S

0 ... 9999

Number of parameters lost during the operating period P714.

P755

Stat. system error

(System faults statistics)

S

0 ... 9999

Number of system faults during the operating period P714.

P756

Stat. Timeout

(Time out statistics)

S

0 ... 9999

Number of Time out errors during the operating period P714.

P757

Stat. Customer error

(Customer faults statistic)

S

0 ... 9999

Number of Customer Watchdog faults during the operating period P714.

P760

Actual mains current

(Actual mains current)

S

0.0 ... 999.9 A

Displays the actual input current.

P799

[-01]

...

[-05]

Op.-time last error

(Operating time, last fault)

0.00 ... ___ h

This parameter shows the operating hours counter status (P714) at the moment of the previous
fault. Array [-01] ... [-05] corresponds to the last fault 1 ... 5.