3 cannord, 3 can for nord frequency inverters, 1 can bus features, physics – NORD Drivesystems BU0060 User Manual

Page 12: 2 canopen features, 3 cannord features, 4 delivery, Cannord, Can for nord frequency inverters, Can bus features, physics, Canopen features

Advertising
background image

CANopen – Supplementary manual options for NORD - Frequency Inverters

12

BU 0060 GB-4112

1.2.3 CANnord

CANnord is a specific bus system from Getriebebau NORD. Further details can be found in Section
4.2.

Pos : 20 /Anl eitungen/ Elektroni k/ Bus s yst eme/1. Einf ührung/CAN open [BU 0060]/C AN bei NORD Frequenzumric ht ern (M er kmal e) [ BU0060] @ 1\ mod_1341317168995_388.doc x @ 28752 @ 2 @ 1

1.3 CAN for NORD frequency inverters

Pos : 21 /Anl eitungen/ Elektroni k/ Bus s yst eme/1. Einf ührung/CAN open [BU 0060]/M er kmal e C AN Bus , Physi k @ 1\ mod_1341317227732_388.doc x @ 28776 @ 3 @ 1

1.3.1 CAN Bus features, physics

• Electrically isolated bus interface

• Transfer rate from 10 kBit/s to 500 kBit/s (optionally up to 1 Mbit/s)

• Connection to frequency inverter via Sub-D9 connector, M12 system connector, RJ45 connector or

screw/plug-in terminals (depending on option/device)

• CAN interface as per specifications 2.0A and 2.0B

• Up to 110 nodes (e.g. frequency inverters) on one bus

• Additional termination resistor (depending on option/device)

• Status display with 2 or 4 LEDs (not with SK 500E/520E/530E)

• External 24V supply required (~70mA for SK 300E/ SK 5xxE/ 700E/ 750E with technology unit

CANopen, ~30mA for SK 5xxE (SK 511E and above) via internal RJ45 connection CANnord/
CANopen)

• TO supports 29 Bit + 11 Bit Identifier

• Internal interface (RJ45) for SK 5xxE (SK 511E and above) only 11 Bit Identifier

Pos : 22 /Anl eitungen/ Elektroni k/ Bus s yst eme/1. Einf ührung/CAN open [BU 0060]/M er kmal e C ANopen @ 1\ mod_1341317959787_388. doc x @ 28800 @ 3 @ 1

1.3.2 CANopen features

• Programming of all frequency inverter parameters using SDO

• Supports DS-301 communications profile and DS-402 drive profile (with technology units)

• Dynamic mapping (4 TPDOs und 4 RPDOs) with technology units

• Heartbeat/ Node Guarding

Pos : 23 /Anl eitungen/ Elektroni k/ Bus s yst eme/1. Einf ührung/CAN open [BU 0060]/M er kmal e C ANnord @ 1\ mod_1341318067232_388. doc x @ 28824 @ 3 @ 1

1.3.3 CANnord features

• Programming of all frequency inverter parameters using SDO

• Setpoint/actual values read/write

• Error messages

• Time out function

Pos : 24 /Anl eitungen/ Elektroni k/FU und Start er/ 1. Allgemei nes/ 1. 2 Lief erung @ 0\ mod_1325780242208_388.doc x @ 5339 @ 2 @ 1

1.4 Delivery

Check the equipment immediately after delivery/unpacking for transport damage such as deformation
or loose parts.

If there is any damage, contact the carrier immediately and carry out a thorough assessment.

Important! This also applies even if the packaging is undamaged.

Pos : 25 /Anl eitungen/ Elektroni k/ Bus s yst eme/1. Einf ührung/CAN open [BU 0060]/ Liefer umf ang [CAN open, SK 300E - SK 750E] @ 1\ mod_1341318451836_388.doc x @ 28848 @ 2 @ 1

Advertising