76

BU 0060 GB-4112

P741

[-01]

...

[-06]

Process data Bus Out

(Process data bus out)

SK 300E /

SK 7x0E

S

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

Series SK 300E

[-01] = Status word

Series SK 7x0E

[-01] = Status word

[-02] = Actual value 1
[-03] = Actual value 2
[-04] = Actual value 3

[-02] = Actual value 1
[-03] = Actual val. 1 High byte
[-04] = Actual value 2
[-05] = Actual value 3

[-05] = Bus I/O Out Bit (P481)

[-06] = Bus I/O Out Bit (P481)

Pos : 133 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P745 – Baugruppen Versi on [ SK 300E] @ 1\ mod_1335791798489_388. doc x @ 25072 @ @ 1

P745

Module version

(Module version)

SK 300E

0.0 ... 3276.7

Version status (software version) of the technology unit (SK TU2-xxx), but only when own
processor is present, i.e. not for SK TU2-CTR.

Have this data available if you have a technical query.

Pos : 134 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P745 – Baugruppen Versi on [ SK 7x0E] @ 1\ mod_1335792003777_388.doc x @ 25096 @ @ 1

P745

[-01]

...

[-03]

Module version

(Module version)

SK 7x0E

S

0000 ... FFFF (hex)

Version status (software version) of the installed option
module(s) but only when own processor is present, i.e. not for
SK TU1-CTR.

Have this data available if you have a technical query.

[-01] = Technology unit

[-02] = Customer unit

[-03] = Special extension unit

Pos : 135 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P746 – Baugruppen Z ust and [SK 300E] @ 1\ mod_1335792492116_388. doc x @ 25120 @ @ 1

P746

Module status

(Module status)

SK 300E

S

0000 ... FFFF (hex)

Shows the actual status (readiness, error, communication) of the technology unit (SK TU2-xxx),
but only when own processor is present, i.e. not for SK TU2-CTR.

Example:

0603

hex

High byte = 06

hex

à Profibus

Low byte = 03

hex

à Module ready + connection to master

Details of the codes specific to the bus can be found in the section "Error monitoring" of the
relevant supplementary instructions.