5 parameters, P740, Process data bus in – NORD Drivesystems BU0060 User Manual

Page 87: P741, Process data bus out

Advertising
background image

5 Parameters

BU 0060 GB-4112

87

P740

[-01]

...

[-23]

Process Data Bus In

(Process data Bus In)

S

0000 ... FFFF (hex)

This parameter informs
about the actual control
word and the setpoints that
are transferred via the bus
systems.

For display, a BUS system
must be selected in P509

[-01 ] = Control word

Control word, source from
P509.

[-02] = setpoint value 1
[-03] = setpoint value 2
[-04] = setpoint value 3
[-05] = setpoint value 4
[-06] = setpoint value 5

Setpoint data from main
setpoint (P510 [-01]).

[-07] = Bus I/O In Bits (P480)

The displayed value depicts all
Bus In Bit sources linked with
"OR".

[-08] = Parameter data In 1
[-09] = Parameter data In 2
[-10] = Parameter data In 3
[-11] = Parameter data In 4
[-12] = Parameter data In 5

Data during parameter transfer:
Order label (AK),Parameter
number (PNU), Index (IND),
Parameter value (PWE 1/2)

[-13] = setpoint value 1
[-14] = setpoint value 2
[-15] = setpoint value 3
[-16] = setpoint value 4
[-17] = setpoint value 5

Setpoint data from the master
function value (Broadcast), if
P509 = 9/10
(P510 [-02])

[-18] = PLC control word

Control word, source PLC

[-19] = setpoint value 1
[-20] = setpoint value 2
[-21] = setpoint value 3
[-22] = setpoint value 4
[-23] = setpoint value 5

Setpoint data from the PLC.

Pos : 165 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P741 – Prozes sdat en Bus Out [ SK 500.. .535E] @ 0\mod_1328177890266_388. doc x @ 13359 @ @ 1

P741

[-01]

...

[-13]

Process Data Bus Out

(Process data Bus Out)

S

0000 ... FFFF (hex)

This parameter provides
information about the actual
status word and the actual
values that are transferred
via the bus systems.

[-01] = Status word

Status word, source from
P509.

[-02] = Actual value 1 (P543)
[-03] = Actual value 2 (P544)
[-04] = Actual value 3 (P545)

[-05] = Bus I/O Out Bit (P481)

The displayed value depicts
all Bus OUT Bit sources linked
with "OR".

[-06 ] = Parameter data Out 1
[-07 ] = Parameter data Out 2
[-08 ] = Parameter data Out 3
[-09 ] = Parameter data Out 4
[-10 ] = Parameter data Out 5

Data during parameter
transfer.

[-11] = Actual value 1 master

function

[-12] = Actual value 2 master

function

[-13] = Actual value 3 master

function

Actual value of master
function
P502 / P503.

Pos : 166 /Anleit ungen/5. / 6. Parametrier ung [BU 0500 / BU 0200]/ Par ameter/ P700-P799/ Paramet er P741 – Prozes sdat en Bus Out [ SK 54xE] @ 0\ mod_1328177956772_388. doc x @ 13382 @ @ 1